Bryant 124A Air Conditioner User Manual


 
19
COMBINATION RATINGS CONTINUED
ARI Ref. No. Model Number IndoorModel Furnace Model Capacity EER SEER Phase
3048398 124ANA060---C CSPH*6012A** 313*AV060135 57500 12.20 14.50 1
3048418 124ANA060---C CSPH*6012A** 315(A,J)AV060110 57500 12.00 14.20 1
3048419 124ANA060---C CSPH*6012A** 315(A,J)AV066135 57500 12.00 14.50 1
3048420 124ANA060---C CSPH*6012A** 315(A,J)AV066155 58000 12.00 14.50 1
3102128 124ANA060---C CSPH*6012A** 353AAV048080 57000 12.00 14.00 1
3102129 124ANA060---C CSPH*6012A** 353AAV060100 57500 12.00 14.00 1
3102130 124ANA060---C CSPH*6012A** 353AAV060120 57500 12.20 14.50 1
3048415 124ANA060---C CSPH*6012A** 355(A,C)AV060080 56000 12.00 14.20 1
3048416 124ANA060---C CSPH*6012A** 355(A,C)AV060100 56000 12.00 14.50 1
3048417 124ANA060---C CSPH*6012A** 355(A,C)AV060120 56000 12.00 14.50 1
3048414 124ANA060---C CSPH*6012A**+TDR 58000 12.00 14.00 1
3048423 124ANA060---C FE4ANB006+UI 59000 12.50 14.50 1
3048424 124ANA060---C FV4BNB006 59000 12.50 14.50 1
3048422 124ANA060---C FX4CN(B,F)060 59500 12.00 14.00 1
3048421 124ANA060---C FY4ANB060 59000 11.50 13.50 1
* Tested combination
EER Energy Efficiency Ratio
SEER —Seasonal Energy Efficiency Ratio
TDR — Time---Delay Relay. In most cases, only 1 m ethod should be used to achieve TDR function. Using more than 1 method in a system may cause
degradation in performance. Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are
equipped with TDR.
TXV Thermostatic Expansion Valve
NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested out door/indoor combinations have been tested in accordance with DOE t est procedures for central air conditioners. Ratings for other
combinations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or fur nace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are significantly affected.
124A