5. ADJUSTMENT
5-19-3. Replacing the movable knife and fixed knife (KE-484C)
1. Open the large shuttle hook cover, remove the bolts (1) and the feed plate (2).
2. Remove the two screws (3) and the two screws (4), and then remove the needle plate (5).
3. Remove the two screws (6) and the feed bar guide plate FF (7).
4. Remove the thread trimmer connecting rod (8) from the connecting rod lever pin (9).
3210
Q3209Q
3208Q2615Q
5.
Remove the movable knife (10) and replace it with a new one. At this time, check that the movable knife (10)
and the fixed knife (11) cut the thread cleanly. If necessary, adjust by using the appropriate movable knife
washer (12) (supplied as accessories).
* Apply grease to the outside of the collar (13) at this time.
6. Install the fixed knife (11) at a distance of 0.5 mm from the needle hole plate (14).
7. Place the thread trimming connecting rod (8) onto the connecting rod lever pin (9), and then install to the
needle plate(5).
KE-430B, 430C series
120