You can start the configuration if a VIP X2 is shown in the list in the left sec-
tion of the window. To do this, click the entry for the unit.
Click the Network tab in the right section of the window. The current network
settings are displayed.
In the IP address field, enter the required IP address (for example
192.168.0.30) and click the Set button at the bottom right of the window.
The new IP address is valid the next time you start the unit.
If required, enter a new subnet mask and additional network data.
Note
You must restart to activate the new IP address, a new subnet mask or a
gateway address.
Restart
You can trigger the restart directly with the assistance of the Configuration Man-
ager:
Right-click the entry for the unit in the list in the left section of the window and
select the Reset command from the context menu.
Additional parameters
You can check and set additional parameters with the assistance of the Config-
uration Manager. You can find detailed information on this in the documentation
for this program.