A# Area Armed
Default: Blank
Selection: Blank, 1 to 128 (1 to 64 for D7412G),
A, B, or C
Activates when the specified area becomes master
armed (exit delay must expire before the relay
activates). The relay remains activated until the area
is disarmed. It does not deactivate during the entry
delay time.
If multiple areas use the same relay, the relay
activates when all areas are armed. It deactivates
when the first area disarms.
Programming a 64 in Area 8’s Silent Alarm
relay causes the Area Armed relay to
energize at the beginning of the exit delay
time.
Keyswitch area armed status with LEDs.
Use a D8129 Module and connect an LED
to display the armed state.
Alternate communication trigger: This
output relay can be used to trigger the
input zone of a device being used as a
slave to report control panel arming status.
A# Area Fault
Default: Blank
Selection: Blank, 1 to 128 (1 to 64 for D7412G),
A, B, or C
The relay activates whenever a controlled (
P##
Type 1, 2, 3
only) Perimeter or Interior point is
faulted. The relay remains activated until all
Perimeter and Interior points in the area are normal.
Keyswitch area armed status with LEDs.
Use a D8129 Module and connect an LED
to light when this relay is activated
indicating that the area is not ready to arm.
A# Duress Relay
Default: Blank
Selection: Blank, 1 to 128 (1 to 64 for D7412G),
A, B, or C
The relay activates when a Duress alarm is
generated from a command center assigned to the
specified area.
0101
0101
0101
Burg Time needs a bell period
programmed and A# Duress Enable must
be Yes. This relay activates steadily
regardless of bell pattern and remains
active until the bell time expires.
A# Perim Fault
Default: Blank
Selection: Blank, 1 to 128 (1 to 64 for D7412G),
A, B, or C
The relay activates when a Controlled Perimeter
point (
P## Type 1
) assigned to the specified area is
faulted. This relay activates regardless of the areas
armed state. This relay provides a steady output until
all Perimeter points in the area return to normal.
This relay does not activate on interior
faults. To detect all area point faults,
program all points as Perimeter points in
the area where this relay is assigned.
A# Silent Alarm
Default: Blank
Selection: Blank, 1 to 128 (1 to 64 for D7412G),
A, B, or C
This relay activates when a point assigned to the
specified area and programmed for
P## Silent Bell
goes into alarm.
0101
0101
0101
Programming Tip #1: Burg Time needs a
bell period programmed. This relay
activates according to the bell pattern and
remains active until the bell time expires or
a valid passcode is entered.
0101
0101
0101
Programming Tip #2: Programming 64 in
Area 8’s Silent Alarm Relay causes the
Area Armed or Perimeter Armed Relay
(see Programming Tip #5) to energize at
the beginning of the exit delay time.
0101
0101
0101
Programming Tip #3: Programming a
non-zero value in Area 5’s Silent Alarm
Relay enables Ground Fault Detect on the
D9412G or D7412G Control Panels. See
the D9412G/D7412G Operation and
Installation Guide regarding Ground Fault
Detect.