Bosch Appliances D7412G Home Security System User Manual


 
D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN EN | 13
Bosch Security Systems | 1/04 | 47775E
Table 6: Modem IIIa
2
Communication Format
Data - User ID Numbers
Point/User Flag
NO
Point/User Flag
YES
000 000
001 to 005 001 to 005
006 to 013 601 to 608
014 to 021 701 to 708
022 to 029 801 to 808
030 to 037 B01 to B08
038 to 045 C01 to C08
046 to 053 D01 to D08
054 to 061 E01 to E08
062 to 069 F01 to F08
070 to 249 000
Table 7: Modem IIIa
2
Communication Format
Data – Point Numbers
Point/User Flag
NO
Point/User Flag
YES
001 to 008 100 to 800
009 to 024 101 to 116
025 to 040 201 to 216
041 to 056 301 to 316
057 to 072 401 to 416
073 to 088 501 to 516
089 to 104 601 to 616
105 to 120 701 to 716
121 to 136 801 to 816
153 to 168 217 to 232
169 to 184 317 to 332
185 to 200 417 to 432
201 to 216 517 to 532
217 to 232 617 to 632
233 – 247 717 to 731
Independent Zone Control Notice: When using
Independent Zone Controls (IZC) to send
Opening/Closing Reports by point, do not duplicate
reporting independent point numbers with User ID
Reports (see Section 3.1 Passcode/Token Worksheet). For
example: If an IZC is connected to Point 8, User ID
8 should not be used.
D6000: Opening/Closing User ID numbers are
identified at the receiver as ZONEs (same
identification as independent points).
Table 8: Zones
User ID Number Zone
1 B
2C
3 D
4E
5 F
66
7 7
88
91 1
92 2
93 3
94 4
95 5
96 0
D6500/D6600 Receiving BFSK Format:
Opening/closing User ID numbers are identified at
the receiver as ZN (same identification as
independent points). The ZN numbers are based on
the tens digit of the User ID number. This only
applies for Users 000 through 099. Users 100
through 249 do not report in BFSK format.
DTMF Dialing
Default: Yes
Selection:
Yes or No
Yes Dials the programmed phone
number(s) using DTMF.
No Pulse dialing only.
Use dual-tone multi-frequency (DTMF) to dial the
central station receiver phone number(s) for event
reports, and/or the RPS.