8.1.2 Combined Units
Delegate microphones with transmission links to
delegate headphones and auxiliary outputs.
General
Frequency response: 125 Hz - 12.5 kHz tolerances
acc. to IEC 914 standard
Total harmonic distortion at overload
at nominal input
level (85 dB SPL): < 0.5%
at max. input
level (110 dB SPL): < 3%
8.2 Mechanical Data
8.2.1 Control and Power Supply Unit
Mounting: free standing on a table top or
mounted in a 19" rack (requires
3HU (Height Units) with bracket
set LBB 3311/00). Information
about how to make the necessary
brackets for table flush mounting
is included.
Dimensions(HxWxD): 84 x 361 x 143 mm (with 5.5
mm feet)
3.4 x 14.2 x 5.6 in (with 0.22 in
feet).
Weight: /00 version 1.5 kg (3.3 lb)
/10 version 1.7 kg (3.7 lb)
8.2.2Delegate/Chairman Units
Dimensions (w x d x h)
without mic.: 124 x 172 x 63 mm
(4.9 x 6.8 x 2.5 in)
Length of mic. from
mounting surface: /00 version, 313 mm (12.3 in)
/50 version, 488 mm (19.2 in)
Weight: 0.9 kg (2.0 lb)
8.3 General Data
8.3.1 System Environmental Conditions
Temperature range
Storage and transport: -20 to +70°C (-4 to +158°F)
Operational: +5 to +45°C (+41 to 113°F)
Ambient humidity
Operational: 20% - 95% RH
Storage and transport: 0% - 99% RH
Air pressure: 600 mBar - 1100 mBar
Safety: acc. to EN 60065 and acc. to
UL6500
Resistance to shock,
vibration, bump
and transport: acc. to IEC68, 5G acceleration
EMC emission: acc. to EN 55103-1 and FCC
rules (part 15), class A
EMC immunity: acc. to EN 55103-2
EMC approvals: affixed with the CE mark EC
directive 89/336 EEC
ESD: acc. to IEC 801-2 and 801-4
Mains harmonics: EN 61000-3-2 and EN61000-3-3
Transport: UN-D 1400