Bosch Appliances CCS 800 Ultro Home Security System User Manual


 
Bosch Security Systems | 2003-06 | 3922 988 54284
CCS 800 Ultro | Installation and Operating Manual en | 17
7 Troubleshooting
Temporary no microphone reaction, and no sound or
distorted sound from unit loudspeakers
Possible cause
Trunk-line overload.
Solution
Reduce load on the trunklines by reducing the
number of units, and/or the length of the trunk
cables.
Acoustic Feedback
Possible cause
Loudspeaker volume too loud.
Solution
- Reduce gain using volume control for delegate/
chairman unit loudspeakers on CPSU.
- If available, switch on Digital Acoustic Feedback
Suppression.
Possible cause
Distance between units too small (microphone to
loudspeaker of other units).
Solution
- Increase distance between units.
- If available, switch on Digital Acoustic Feedback
Suppression.
Possible cause
Too close to microphone units, when using open
headphones.
Solution
- Increase the distance between headphone and
microphone or disconnect headphones when not
in use.
- If available, switch on Digital Acoustic Feedback
Suppression.
Part of system not working
Possible cause
Interrupted trunk-line cabling.
Solution
Check the trunk-line cabling connections between
the units and the CPSU, also use the test function on
the CPSU.
No sound via delegate/chairman loudspeakers
Possible cause
Insertion switch in wrong position.
Solution
Check if insertion switch at the rear of the CPSU is
in position "1".
Possible cause
Volume control position.
Solution
Check if the volume control for delegate/chairman
loudspeakers on the CPSU is not in the fully counter
clockwise position.
Possible cause
Microphone active or headphone connected.
Note
Units with active microphone or connected
headphone(s) have their loudspeakers switched
off.