Bosch Appliances 100 Combi Boiler Boiler User Manual


 
6
|
Bosch Greenstar Applications Manual
Bosch Thermotechnology Corp.Data subject to change
1.3 FB100 Remote Control & Room Sensor
The FB100 can only be connected
to systems with FW200 and a boiler
with BUS-enabled Heatronic 3.
The FB100 is a remote room sensor and user interface
that is used to display device and system information
and to change the settings of that particular zone.
The FB100 is designed for wall mounting.
In connection with the IPM2 module, the FB100
controls the assigned heating circuit using a timer
program. Three weekly heating programs with six
switch points per day are available for a heating circuit
(one program is active).
Maximum of four FB100 in a heating system with
FW200.
In case of power failure, the display will be off. All
settings are saved.
Scope of delivery
2
4
1
3
8
Fig. 2 FB100 Remote Control & Room Sensor
1 Upper part of remote control
2 Base for wall-mounting
3 Top cover