Bosch Appliances 100 Combi Boiler Boiler User Manual


 
Applications Manual Bosch Greenstar | 5
Bosch Thermotechnology Corp.
Data subject to change
1.2 FW200 Boiler Energy Management
System
The Boiler Energy Management System includes the
FW200 user programming interface with integrated
outdoor reset control.
In connection with the IPM2 module the FW200 offers
an outdoor reset control for two heating zones and
DHW generation with time programs:
Central heating
: Six weekly heating
programs with six programmable switch points
per day (one program is active).
DHW
: weekly DHW program with six switch
points per day.
DHW Recirculation pump program.
Options:
Remote control and room sensor FB100
provides status information and a programming
interface in each zone.
Module ISM2 for solar DHW heating and solar
space heating support.
Programs and settings are stored in a permanent
memory and remain even during power outages.
Installation options:
In the boiler
Wall-mounted as a remote room sensor
Scope of delivery
2x
2x
5
2
4
1
3
8
Fig. 1 FW200 Energy Management System
1 Controls top section
2 Base for wall-mounting
3 Top cover
4 Installation and operating instructions
5 Outdoor temperature sensor with mounting kit