2.7 System 7: Greenstar Heating Boiler in a
single zone system with DHW tank loading
Summary:
Single boiler with primary/secondary piping con guration
supplying one heating zone. Outdoor reset with FW200
controller with built-in room sensor mounted in the living
space for room feedback.
Use this design where System 3 cannot be used due to
too great a system pressure drop. Primary/secondary
piping is also required for radiant oor and panel radiator
applications.
Primary/secondary piping isolates the system ow from
the boiler ow and prevents the system from in uencing
boiler performance.
This system is identical to System 5 with an added indirect
red DHW tank.
Use this system over System 6 where the combi-boiler
does not have the required DHW volume ow capacity;
keep in mind however that the tank capacity is not endless
compared to that of the combi-boiler.
In detail:
The FW200 is an outdoor temperature based controller
with room temperature in uence. The controller adjusts
the heating curve (boiler supply temperature) according
to outdoor temperature. When the FW200 is wall mounted
as a room sensor, it uses room temperature to adjust the
heating curve and modify boiler supply temperature ac-
cordingly.
FW200 provides warm weather shutdown.
For temperature sensitive radiant oor applications, install
a thermostatic tempering valve for overheat protection.
Required components:
Greenstar heating boiler.
FW200 controller in the room.
Primary/secondary piping and system pump.
Thermostatic mixing valve (optional - overheat
protection for temperature sensitive floors).
Indirect Fired DHW Tank.
Tank loading pump of sufficient capacity.
Additional instructions:
See manufacturer’s installation and operating instructions.