Berkley B2XRKS Water Pump User Manual


 
Page 4 F00633
Pump Foundation
Installation
Typical Installations
Drainage
Drainage
Pump or
Motor Frame
1/2" or thicker
Sole Plate tapped
for hold down bolts
Anchor
Bolts
Pump or
Motor Frame
Shims
for alignment
Anchor
Bolt
Steel
Channel
Concrete
Foundation
Grout
Dam
Drainage
Wedges
Various Heights
Concrete
Foundation
Shims
Pump and Motor
Base
1300 1094
Tack
Weld
Concrete Foundation
Grout
There are several types of permanent pump/
foundation installations in use. Those pictured above
are typical.
If grout is used, top of concrete should be left rough
to provide a good bonding surface.
Foundation should slope away from pump to prevent
liquid from pooling.