Belkin PF50 Humidifier User Manual


 
Troubleshooting
PureAV Power Console
22
Power Console is not providing power.
Check to ensure that the Power Console is plugged into a properly
earthed AC wall socket. Some sockets require a wall switch to be
turned on in order to deliver power to the socket.
Too many devices may be plugged into the Power Console, which are
overloading the unit and tripping the overload circuit breaker. The
Power Console is not designed to handle current loads larger than
10 Amps or 2400 watts. Try unplugging some devices and resetting
the circuit breaker located on the end of the Power Console.
To reset the circuit breaker: Wait at least 10 minutes after the
circuit breaker was tripped before attempting to reset the breaker.
Press the button located next to the power cable on the back of
the unit to reset. Power should be restored to the sockets on the
Power Console.
Your components may be plugged into a “Switched” socket and
the socket is not switched on. Check to ensure that the “Switched
ON” indicator on the Control Panel is illuminated. If the light is not
illuminated, press the “Switched” button on the front of the Power
Console unit until the “Switched ON” indicator is illuminated. You
should now have power to all of the switched sockets.
Your components may not be turned on. Power may be flowing from
the Power Console, but if the power switch on your component is
not turned on, your component cannot receive power. Turn on your
component’s power switch.
The surge protection components may be expired. The Power Console
is designed to stop delivering power to all sockets when the surge-
protection circuitry is not functioning properly or is expired. Call
Belkin Customer Service for assistance.
The Power Console may be defective. Call Belkin Customer Service
for assistance.
“Earth Fault” indicator is lit.
Check to make sure that the Power Console is plugged into an
earthed AC wall socket. Do not use any plug adapters.
If the “Earth Fault” indicator is still lit, you have an earth-wiring
problem. Connecting the Power Console to an improperly earthed
socket is not safe and will void all Belkin warranties. Unplug the
Power Console and consult an electrician to properly earth the
socket. If the socket is properly earthed and the “Earth Fault”
indicator is still lit, the Power Console may be malfunctioning. Please
call Belkin Customer Service for assistance.