Beckett FII 85 Burner User Manual


 
RWB 6104 BAFII R01 Page 13
Stop
Screw
AFII 85 AFII 100 AFII 150
0 0.40-0.65 0.5-0.65 0.75-1.00
1 - 0.6-0.75 0.85-1.10
2 - 0.65-0.80 0.95-1.15
3 0.60-0.75 0.65-0.90 0.95-1.20
4 - 0.75-0.95 1.10-1.25
5 0.70-0.85 0.85-1.00 1.15-1.35
6 - 0.95-1.10 1.15-1.40
7 - - 1.25-1.50
8 - - 1.30-1.50
HLX Firing Rate
Firing Rate
@ 140 psig
AFII 85 AFII 100 AFII 150
0.40-0.65 3 - -
0.60-0.75 4 3 -
0.70-0.85 5 4 -
0.75-1.00 - 5 2
0.95-1.20 - - 3
1.15-1.35 - - 4
1.25-1.50 - - 5
HLX Air Dial Setting
Trained Service Technician’s Regular Maintenance
Head AFII 85 AFII 100 AFII 150
FB0 0.40-0.65 0.55-0.75 0.75-1.00
FB3 0.55-0.85 0.55-1.10 0.85-1.20
FB4 - 0.75-1.10 1.10-1.25
FB6 - 0.85-1.15 1.15-1.35
FBX Firing Rate
Firing Rate @
140 psig
AFII 85 AFII 100 AFII 150
0.40-0.65 3 - -
0.60-0.75 4 3 -
0.70-0.85 5 4 -
0.75-1.00 - 5 2
0.95-1.20 - - 3
1.15-1.35 - - 4
1.25-1.50 - - 5
FBX Air Dial Setting