Axis Communications Q6045-E Home Security System User Manual


 
AXIS Q6045-E Mk II PTZ Dome Network Camera
Access the Product
The default administrator user name root is permanent and cannot be deleted. If the password for root is lost, the product must be
reset to the factory default settings. See Reset to Factory Default Settings on page 56.
To set the password via a standard HTTP connection, enter it directly in the dialog.
To set the password via an encrypted HTTPS connection, follow these steps:
1. Click Use HTTPS.
A temporary certicate (valid for one year) is created, enabling encryption of all trafc to and from the product, and the
password can now be set securely.
2. Enter a password and then re-enter it to conrm the spelling.
3. Click OK. The password has now been congured.
The Live View Page
The controls and layout of the Live View page may have been customized to meet specic installation requirements and user
preferences. Consequently, some of the examples and functions featured here may differ from those displayed in your own Live View
page. The following provides an overview of each available control.
Controls on the Live View Page
Select a stream prole for the Live View page from the Stream Prole drop-down list. For information about how
to congure stream proles, see page 18.
The Manual Trigger button is used to trigger an action rule from the Live View page. For information about how to
congure and enable the button, see Manual Trigger on page 10.
Click Snapshot to save a snapshot of the video image. This button is primarily intended for use when the
AXIS Media Control viewer toolbar is not available. Enable this button from Live View Cong > Action Buttons.
The product’s fans are controlled by the ambient temperature and are turned on and off automatically. If required,
the fans can be activated manually by clicking the Fan button. To show the button, go to Setup > Live View Cong.
Under Action Buttons, select Show fan button and specify the number of minutes the fans should be activated.
The product’s heater is controlled by the ambient temperature and is turned on and off automatically. If required,
the heater can be activated manually by clicking the Heater button. To show the button, go to Setup > Live
View Cong. Under Action Buttons, select Show heater button and specify the number of minutes the heater
should be activated.
Enable or disable the Gatekeeper by selecting On or Off from the drop-down list. For more information about the
Gatekeeper, see page 27.
Manual Trigger
The Manual Trigger is used to trigger an action rule from the Live View page. The manual trigger can for example be used to
validate actions during product installation and conguration.
To congure the manual trigger:
1. Go to Setup > Events.
10