Avalon Stoves Cedar EF Stove User Manual


 
Installation Addenda 39
Travis Industries 4122104 93508117
ADDENDUM #2 Interior Masonry Chimney Conversions
Follow the requirements and
use the equipment listed in
the illustration to the right to
install this appliance into an
interior masonry chimney.
Maximum vertical rise is 40'
Minimum vertical rise is 10'
See the chart on page 14 for
determining the correct
restrictor position.
NOTE: these restrictor
positions are based upon lab
tests. The ideal restrictor
position may vary slightly.
The entire chimney system
must be air-tight. Make sure to
seal the flashing, clean-out,
and thimble connection, and to
inspect the chimney.
#711 Flex Liner (4 dia.)
(or other UL 1777 Gas
Liner)
Co-Axial Straight
Lengths
#991 High Wind
Termination
#990 90° Elbow
Flashing (included in
#934 Masonry
Conversion Kit
Make sure the coaxial pipe
maintains a 1 clearance to any
combustible. The vent must be
sealed air-tight.
High-Temp.
Silicone
Connector with Cover
(included in #934 Masonry
Conversion Kit)
Interior Masonry Chimney
Standard Masonry Fireplace
Connector (included in #934
Masonry Conversion Kit)
secured and sealed to
block-off plate.
Flashing (included in
#934 Masonry
Conversion Kit)
#991 High Wind
Termination
#711 Flex Liner (4 dia.)
(or other UL 1777 Gas Liner)
The entire chimney system
must be air-tight. Seal the
connector cover and inspect
the chimney.
Make sure the coaxial pipe
maintains a 1 clearance to any
combustible. The vent must be
sealed air-tight.
High-Temp.
Silicone