Installation (for qualified installers only) 9
Travis Industries 4122104 93508117
Approved Vent
Configurations
Restrictor Position
• A vent restrictor is built
into the appliance to
control the flow rate of
exhaust gases. This
ensures proper flames
for the wide variety of
vent configurations.
Depending upon the
vent configuration,
you may be required to
adjust the restrictor
position. The charts
for approved vent
configurations
describe which
position the vent
restrictor must be in.
NOTE:
if the vent is already
installed, prop up the
stove top to adjust the
restrictor. Take care to
not scratch the vent.
To Adjust the Restrictor
NOTE:
The restrictor is
shipped in
position #1.
This restrictor is
in position # 6
Lift the cotter pin out.
a
Slide the restrictor
adjustment rod in.
b
Replace the cotter pin
through the correct
hole on the restrictor
adjustment rod.
c
Restrictor
Positions
# 2
# 4
# 6
# 3
# 5
# 1
Loosen these
four screws
and tilt the
stove top up to
access the
restrictor .
1/4" Nutdriver
Measuring
Vent Lengths
Vent Horizontal Run
(measure from the closest edge of the
starter section to the end of the
termination)
Vent Height is calculated
to the top of the vent on
horizontal terminations
and to the top of the
termination on vertical
terminations.
Vent
Height
The starter section is
3/8" above the top