Assa Model 34 Door User Manual


 
Rev. A.5, 8/03 Page- 6
sheet rock do not constitute a secure mounting substrate). Note that when the roll pin bushings
are used, they protrude through the Z bracket and interfere with the Z bracket cover. If a
Senstat lock is being employed, the roll pin bushings must be used to provide insulation. They
should be cut with a hacksaw to function in the bracket. If the lock is not Senstat, omit use of
the roll pin bushings and drill 3/8" (9.5mm) diameter holes for the roll pins instead of 1/2"
(12.7mm). Read sections 2.3, 2.3.1, and 2.3.2 for additional general information on mounting.
FIG. 6: F MAGNET DIMENSIONS
Blind Nut
PN# BN-250 or
PN# BN-6MM (Metric)
(Pack of 24 with tool)
Tamper Cap
PN# FC-1 (Pack of 24)
1/4-20 x 2 1/2" Cap Screw
PN# SCS-25 or
6mm-1mm x 60mm
PN# SCS-60mm (Metric)
Pack of four screws
G
o
l
d
W
a
s
h
e
r
P
N#
F
W
-
1
(
P
a
c
k
o
f
2
4
)
Model 62F
Model 32F
If "G" option is furnished, the
wire cable emerges from a 3/4"
male; 1/2" female conduit fitting
on the end of the magnet (62
and 82 models only)
Length Width Depth
32 8" 1.88 1.5
(mm) 203 47.8 38.1
62 8" 2.9 1.75
(mm) 203 73.7 44.5
82 12" 2.9 1.75
(mm) 305 73.7 44.5