Assa Model 34 Door User Manual


 
Rev. A.5, 8/03 Page- 9
FIG. 9: USE OF THE UMB BRACKET WITH THE MODEL 34 MAGNALOCK
STOP
HEADER
DOOR
STRIKE
MAGNET
BLADE
UMB BRACKET
ALUMINUM DOOR AND FRAME
WITH BLADE STOP
STOP
HEADER
DOOR
STRIKE
MAGNET
UMB BRACKET
ALUMINUM DOOR AND FRAME
WITH BLADE STOP
NOTE HOW BRACKET CAN BE REVERSED TO COPE WITH DIFFERENT STOP THICKNESSES
THE TWO LARGER HOLES ARE FOR THE
CABLE EXIT. THE TWO THREADED HOLES
ACCEPT THE MAGNET MOUNTING SCREWS.
THE REMAINING FIVE HOLES ACCEPT
DIFFERENT FASTENER TYPES TO MOUNT
TO DIFFERENT HEADERS.
Note that we have said "100% glass door". Some doors that appear to be glass are actually
laminated with plastic. If the Magnalock with glass door bracket is used on this type of
door, it is possible that failure will occur via delamination.
In some cases the header of a glass door is vertical glass. The magnet can be mounted on
such a header by using a 3" X 3" aluminum angle bracket (part number HEB-3G). The bracket
is glued to the vertical glass header with Securitron's adhesive kit for glass and the magnet is
screwed to the bracket.