Ariston 41-116-37 Boiler User Manual


 
27
installation
Fitting instructions for:
• Internal mechanical time clock
• Internal RF receiver for Ariston programmable
room thermostat
These instructions to be used in conjunction with the appliance
installation instructions. Ensure the appliance is electrically
isolated before working on the appliance.
Remove the outer casing, and remove the front control panel by
removing the 2 securing screws.
Remove the clock blanking plate (or existing clock if  tting the RF
receiver in a product with an existing mechanical clock) from the
front control panel of the boiler.
Using the 4 securing screws supplied with the clock accessory,
secure the clock/RF receiver into position, ensuring the accessory
is oriented correctly.
Connect the wires to the clock accessory using the spade
connectors (see  g. 1 for wiring con guration)
Fig. 1
Reassemble appliance, turn on electrical supply and operate
accessory using instructions supplied.
1 Red Wire
2 Double Black wire
3 Black wire
4 Spare terminal
5 Blue wire
Rear view of
Time clock
Accessory