Ariston 41-116-04 Boiler User Manual


 
18
The boiler can be converted to use either methane (natural) gas (G20)
or LPG (G30 - G31) by an Authorised Service Centre.
The operations that must be performed are the following:
1. Replace the jets on the main burner (see table in section 5);
2. Pay attention to put the gas restrictor if convert the boiler from NG to
GPL and to take it out when pass from LPG to NG;
2. Adjust the maximum and minimum thermal capacity values for the boiler
(see table in section 5);
3. Replace the gas rating plate;
4. Adjust the maximum thermal power setting;
5. Adjust the soft-light feature (open the cover of the regulation screw on the
gas valve (see F
IG. 5.1). Rotate clockwise from min. to max. as per
installation requirements).
5.1 C
HANGING THE
T
YPE OF GAS
The outlet pressure of the gas cock is obtained by completely loosening the screw on the solenoid.The
maximum pressure of the gas to the burner will be equal to the nominal delivery pressure minus the
head loss within the gas valve.
[1 mbar = 10,197 mmc.a.]
5. GAS ADJUSTMENTS
CATEGORY II2H3+ Methane Gas
G20
Liquid Butane Gas
G30
Liquid Propane Gas
G31
45.67
20
17
1.30
---
1.22
----
8.3
80.58
29
20
0.77
2.9
----
0.91
22.9
80.58
37
25
0.77
2.9
----
0.90
29.5
VG002Ab
TABLE 5.1
F
IG. 5.1
Lower Wobbe Index (15°C;1013mbar) MJ/m
3
h
Nominal Delivery Pressure mbar
Minimum Delivery Pressure mbar
10 RFFI
Main Burner: n. 8 jets (ø)mm
Restrictor ø
Consumption (15°C; 1013mbar) m
3
/h
Consumption (15°C; 1013mbar) Kg/h
Gas Burner Pressure:
max - min mbar