heaters, the burners of a tankless water heater must be
very powerful to heat water instantaneously since they do
this only at the time hot water is actually being used. It is
therefore imperative that the gas pressure requirement
be met exactly. Insufficient gas pressure will directly affect
the water temperature at the time of usage. See pages 2
and 13 respectively for correct gas pressure settings and
where gas pressures are taken.
4. Btu input is too low due to insufficient gas supply
Make sure your main gas line is fully opened. If using LP
gas, be sure that the size of the propane tank is adequate
to supply the required gas pressure.
5. Cold water is mixing with the hot water between
the AquaStar and the outlet
Compare water temperature at outlet of the AquaStar (hold
the AquaStar’s outlet pipe with your hand) and at the tap.
If these two are very different, check for mixing valve or
plumbing crossover (see “MAIN BURNERS WILL NOT
IGNITE...” paragraph #6). Where automatic “anti-scald”
valves are required by code, lower the temperature setting
on the AquaStar as much as possible and balance the
pressure between cold and hot water after the AquaStar.
6. Parts in water flow valve are corroded so that the
gas passage is not fully opening.
Contact your service person or Controlled Energy.
HOT WATER TEMPERATURE FLUCTUATES
1. Unbalanced pressure in waterlines
The added restriction caused by the Aquastar in the hot
water system can result in uneven pressures between the
cold and the hot. In such cases when mixing cold water at
the tap, the lower hot water pressure may be overpowered
by a much higher cold water pressure, which may cause
the Aquastar burners to shut down. Make sure faucet
aerators or shower heads are free of minerals.
Do not
add any flow restrictor to the shower head.
2. Cold water is mixing with the hot water between
the AquaStar and the outlet
See #6 under “Burners do Not Ignite When Hot Water
Turned On”.
3. Inlet water pressure is erratic due to inadequate
supply water pressure or saturated pressure tank
on well system
Check the inlet water pressure. On a private well, raise
minimum pressure setting to 30 psi. Confirm that the
pressure tank is not water logged.
4. Insufficient gas pressure
Check gas pressure requirements (page 2) and consult
gas service person.