CONDENSING UNIT SPECIFICATIONS
8
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/
circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.
*
Up to 24' in equivalent line length
(1)
Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes.
(2)
Maximum Overcurrent Protection Device: MUST use Time Delay Fuses or HACR type Circuit Breaker of the same size as noted.
ASX140181D* / ASX140421D*
ASX140181D* ASX140421D*
Cooling Capacity, BTUH 18,000 40,000
Compressor
R.L. Amps 9.00
16.7
L.R. Amps 48.0
79.0
Low Pressure Switch
Open
Close
N/A
N/A
22 PSIG
50 PSIG
High Pressure Switch
Open
Close
610 PSIG
420 PSIG
610 PSIG
420 PSIG
Condenser Fan Motor
Horsepower 1/8 1/6
F.L. Amps 0.7 0.9
Liquid Line, Inches O.D.* 3/8" 3/8"
Suction Line, Inches O.D.* 3/4" 7/8"
Refrigerant Charge 73.0
140.0
Power Supply 208/230-60-1 208/230-60-1
Minimum Circuit Ampacity
(1 )
12
21.8
Maximum Overcurrent Device
(2)
20
35
Electrical Conduit Size
Power Supply (Inches) 1/2 or 3/4 1/2 or 3/4
Approximate Shipping Weight 146 184