Amana ASX 14 SEER Air Conditioner User Manual


 
29
COOLING PERFORMANCE DATA
ASX140421C* / D*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
MODEL: ASX140421C*/CA*F4860*6B*
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 35.1 36.4 39.9 - 34.3 35.6 39.0 - 33.5 34.7 38.0 - 32.7 33.9 37.1 - 31.0 32.2 35.2 - 28.8 29.8 32.7 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.41 - 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.79 0.66 0.46 -
Delta T 18 16 12 - 18 16 12 - 18 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
1225 KW 2.06 2.11 2.18 - 2.23 2.29 2.37 - 2.39 2.45 2.53 - 2.52 2.59 2.68 - 2.64 2.70 2.80 - 2.74 2.81 2.91 -
AMPS 8.8 9.0 9.3 - 9.5 9.7 10.0 - 10.3 10.5 10.9 - 11.0 11.3 11.6 - 11.7 12.0 12.4 - 12.4 12.7 13.1 -
HI PR 224 242 255 - 252 271 286 - 286 308 326 - 326 351 371 - 367 395 417 - 406 436 461 -
LO PR 108 114 125 - 114 121 132 - 118 126 137 - 124 132 144 - 130 138 151 - 134 143 156 -
MBh 38.1 39.4 43.2 - 37.2 38.5 42.2 - 36.3 37.6 41.2 - 35.4 36.7 40.2 - 33.6 34.9 38.2 - 31.2 32.3 35.4 -
S/T 0.72 0.60 0.41 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.45 - 0.82 0.68 0.47 - 0.82 0.69 0.48 -
Delta T 17 15 11 - 18 15 11 - 18 15 12 - 18 15 12 - 17 15 11 - 16 14 11 -
70 1450 KW 2.11 2.16 2.24 - 2.29 2.35 2.43 - 2.45 2.51 2.60 - 2.60 2.66 2.75 - 2.71 2.78 2.88 - 2.82 2.89 2.99 -
AMPS 9.0 9.2 9.5 - 9.7 10.0 10.3 - 10.6 10.8 11.2 - 11.3 11.6 12.0 - 12.0 12.3 12.7 - 12.8 13.1 13.5 -
HI PR 231 249 263 - 260 279 295 - 295 318 336 - 336 362 382 - 378 407 430 - 418 450 475 -
LO PR 111 118 129 - 117 125 136 - 122 129 141 - 128 136 148 - 134 143 156 - 139 147 161 -
MBh 38.4 39.8 43.6 - 37.5 38.9 42.6 - 36.6 38.0 41.6 - 35.8 37.1 40.6 - 34.0 35.2 38.6 - 31.5 32.6 35.7 -
S/T 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.84 0.70 0.49 -
Delta T 16 14 11 - 17 14 11 - 17 14 11 - 17 14 11 - 16 14 11 - 15 13 10 -
1575 KW 2.12 2.17 2.25 - 2.30 2.36 2.44 - 2.46 2.52 2.61 - 2.60 2.67 2.76 - 2.72 2.79 2.89 - 2.83 2.89 3.00 -
AMPS 9.0 9.2 9.6 - 9.8 10.0 10.3 - 10.6 10.9 11.2 - 11.3 11.6 12.0 - 12.1 12.4 12.8 - 12.8 13.1 13.6 -
HI PR 232 250 264 - 260 280 296 - 296 319 337 - 337 363 383 - 380 408 431 - 419 451 476 -
LO PR 111 118 129 - 117 125 136 - 122 130 142 - 128 136 149 - 134 143 156 - 139 148 161 -
MBh 35.7 36.8 39.8 42.7 34.9 35.9 38.9 41.7 34.1 35.1 38.0 40.7 33.2
34.2
37.0 39.7 31.6 32.5 35.2 37.8 29.2 30.1 32.6 35.0
S/T 0.79 0.70 0.53 0.34 0.81 0.73 0.55 0.35 0.83 0.75 0.56 0.36 0.86
0.77
0.58 0.38 0.89 0.80 0.61 0.39 0.90 0.81 0.61 0.39
Delta T21191611212016112120161121
20
16 11 21 20 16 11 20 18 15 10
1225 KW 2.08 2.13 2.20 2.28 2.25 2.31 2.39 2.47 2.41 2.47 2.56 2.65 2.55
2.61
2.70 2.80 2.67 2.73 2.83 2.93 2.77 2.83 2.94 3.04
AMPS 8.8 9.1 9.4 9.7 9.6 9.8 10.1 10.5 10.4 10.6 11.0 11.4 11.1
11.4
11.8 12.2 11.8 12.1 12.5 13.0 12.5 12.8 13.3 13.8
HI PR 227 244 258 269 254 274 289 302 289 311 329 343 330
355
375 391 371 399 421 439 410 441 466 486
LO PR 109 116 126 134 115 122 133 142 119 127 139 148 125
133
145 155 131 140 152 162 136 144 158 168
MBh 38.7 39.8 43.1 46.3 37.8 38.9 42.1 45.2 36.9 38.0 41.1 44.1 36.0
37.1
40.1 43.1 34.2 35.2 38.1 40.9 31.7 32.6 35.3 37.9
S/T 0.81 0.73 0.55 0.35 0.84 0.76 0.57 0.37 0.87 0.77 0.59 0.38 0.89
0.80
0.60 0.39 0.93 0.83 0.63 0.40 0.94 0.84 0.63 0.41
Delta T20181510201915112019151120
19
15 11 20 19 15 10 19 17 14 10
75 1450 KW 2.13 2.18 2.26 2.34 2.32 2.37 2.45 2.54 2.48 2.54 2.63 2.72 2.62
2.68
2.78 2.88 2.74 2.81 2.91 3.01 2.84 2.91 3.02 3.13
AMPS 9.1 9.3 9.6 10.0 9.8 10.1 10.4 10.8 10.7 10.9 11.3 11.7 11.4
11.7
12.1 12.5 12.2 12.5 12.9 13.4 12.9 13.2 13.6 14.2
HI PR 234 252 266 277 262 282 298 311 298 321 339 354 340
366
386 403 382 411 434 453 422 454 480 501
LO PR 112 119 130 138 118 126 137 146 123 131 143 152 129
137
150 160 135 144 157 167 140 149 163 173
MBh 39.1 40.2 43.6 46.8 38.2 39.3 42.5 45.7 37.3 38.4 41.5 44.6 36.4
37.4
40.5 43.5 34.5 35.6 38.5 41.3 32.0 32.9 35.7 38.3
S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.60 0.38 0.91
0.81
0.62 0.40 0.95 0.85 0.64 0.41 0.95 0.85 0.65 0.42
Delta T19171410191814101918141019
18
15 10 19 18 14 10 18 16 13 9
1575 KW 2.14 2.19 2.27 2.35 2.32 2.38 2.46 2.55 2.48 2.54 2.63 2.73 2.63
2.69
2.79 2.89 2.75 2.81 2.92 3.02 2.85 2.92 3.03 3.14
AMPS 9.1 9.3 9.6 10.0 9.9 10.1 10.4 10.8 10.7 11.0 11.3 11.8 11.4
11.7
12.1 12.6 12.2 12.5 12.9 13.4 12.9 13.2 13.7 14.2
HI PR 234 252 266 278 263 283 299 312 299 322 340 355 341
367
387 404 383 413 436 454 424 456 481 502
LO PR 112 119 130 139 119 126 138 147 123 131 143 153 130
138
150 160 136 144 158 168 140 149 163 174
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions KW=Total system power AMPS=outdoor unit amps (comp.+fan)