Amana ASX 14 SEER Air Conditioner User Manual


 
23
COOLING PERFORMANCE DATA
ASX140361B* / C*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
MODEL: ASX140361B*/CA*F3642*6C*
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 30.4 31.5 34.5 - 29.7 30.8 33.7 - 29.0 30.0 32.9 - 28.3 29.3 32.1 - 26.9 27.8 30.5 - 24.9 25.8 28.2 -
S/T 0.68 0.57 0.39 - 0.71 0.59 0.41 - 0.72 0.61 0.42 - 0.75 0.62 0.43 - 0.78 0.65 0.45 - 0.78 0.65 0.45 -
Delta T 18 16 12 - 18 16 12 - 18 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
1050 KW 2.17 2.21 2.28 - 2.33 2.38 2.46 - 2.48 2.54 2.62 - 2.61 2.67 2.76 - 2.73 2.79 2.88 - 2.82 2.89 2.98 -
AMPS 7.6 7.8 8.0 - 8.2 8.4 8.6 - 8.9 9.1 9.4 - 9.5 9.7 10.0 - 10.1 10.3 10.7 - 10.7 10.9 11.3 -
HI PR 218 235 248 - 245 264 279 - 279 300 317 - 318 342 361 - 357 384 406 - 395 425 449 -
LO PR 103 109 119 - 108 115 126 - 113 120 131 - 118 126 137 - 124 132 144 - 128 136 149 -
MBh 32.9 34.1 37.4 - 32.2 33.3 36.5 - 31.4 32.5 35.6 - 30.6 31.7 34.8 - 29.1 30.2 33.0 - 26.9 27.9 30.6 -
S/T 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.78 0.65 0.45 - 0.80 0.67 0.47 - 0.81 0.68 0.47 -
Delta T 18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
70 1200 KW 2.22 2.27 2.34 - 2.39 2.45 2.53 - 2.55 2.60 2.69 - 2.68 2.74 2.83 - 2.80 2.86 2.96 - 2.90 2.96 3.06 -
AMPS 7.8 8.0 8.2 - 8.4 8.6 8.9 - 9.1 9.3 9.6 - 9.7 10.0 10.3 - 10.4 10.6 11.0 - 11.0 11.2 11.6 -
HI PR 225 242 256 - 253 272 287 - 287 309 327 - 327 352 372 - 368 396 419 - 407 438 462 -
LO PR 106 113 123 - 112 119 130 - 116 124 135 - 122 130 142 - 128 136 149 - 132 141 154 -
MBh 33.9 35.1 38.5 - 33.1 34.3 37.6 - 32.3 33.5 36.7 - 31.5 32.7 35.8 - 30.0 31.1 34.0 - 27.8 28.8 31.5 -
S/T 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.85 0.71 0.49 -
Delta T 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 16 14 11 -
1350 KW 2.24 2.29 2.36 - 2.41 2.47 2.55 - 2.57 2.63 2.71 - 2.70 2.77 2.86 - 2.82 2.89 2.98 - 2.92 2.99 3.09 -
AMPS 7.9 8.0 8.3 - 8.5 8.7 9.0 - 9.2 9.4 9.7 - 9.8 10.1 10.4 - 10.5 10.7 11.1 - 11.1 11.3 11.7 -
HI PR 227 245 259 - 255 275 290 - 290 312 330 - 331 356 376 - 372 400 423 - 411 442 467 -
LO PR 107 114 124 - 113 120 131 - 117 125 136 - 123 131 143 - 129 137 150 - 134 142 155 -
MBh 30.9 31.8 34.4 37.0 30.2 31.1 33.6 36.1 29.5 30.3 32.8 35.2 28.7
29.6
32.0 34.4 27.3 28.1 30.4 32.7 25.3 26.0 28.2 30.3
S/T 0.77 0.69 0.52 0.34 0.80 0.72 0.54 0.35 0.82 0.74 0.56 0.36 0.85
0.76
0.58 0.37 0.88 0.79 0.60 0.38 0.89 0.80 0.60 0.39
Delta T21191611212016112120161121
20
16 11 21 19 16 11 20 18 15 10
1050 KW 2.18 2.23 2.30 2.38 2.35 2.41 2.48 2.57 2.50 2.56 2.64 2.73 2.64
2.70
2.79 2.88 2.75 2.81 2.91 3.01 2.85 2.91 3.01 3.11
AMPS 7.7 7.8 8.1 8.4 8.3 8.5 8.7 9.0 9.0 9.2 9.5 9.8 9.6
9.8
10.1 10.5 10.2 10.4 10.8 11.2 10.8 11.0 11.4 11.8
HI PR 221 238 251 262 248 267 281 294 282 303 320 334 321
345
365 380 361 388 410 428 399 429 453 473
LO PR 104 110 120 128 110 117 127 135 114 121 132 141 120
127
139 148 125 133 146 155 130 138 151 160
MBh 33.5 34.5 37.3 40.0 32.7 33.7 36.4 39.1 31.9 32.9 35.6 38.2 31.1
32.1
34.7 37.2 29.6 30.5 33.0 35.4 27.4 28.2 30.5 32.8
S/T 0.80 0.72 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88
0.79
0.60 0.38 0.91 0.82 0.62 0.40 0.92 0.83 0.62 0.40
Delta T21191611211916112119161121
19
16 11 21 19 16 11 19 18 15 10
75 1200 KW 2.24 2.29 2.36 2.44 2.41 2.47 2.55 2.63 2.57 2.63 2.71 2.80 2.71
2.77
2.86 2.96 2.82 2.89 2.98 3.09 2.92 2.99 3.09 3.20
AMPS 7.9 8.0 8.3 8.6 8.5 8.7 9.0 9.3 9.2 9.4 9.7 10.1 9.8
10.1
10.4 10.8 10.5 10.7 11.1 11.5 11.1 11.3 11.7 12.2
HI PR 228 245 259 270 255 275 290 303 290 312 330 344 331
356
376 392 372 400 423 441 411 442 467 487
LO PR 107 114 124 132 113 120 131 140 117 125 136 145 123
131
143 152 129 137 150 160 134 142 155 165
MBh 34.5 35.5 38.4 41.2 33.7 34.7 37.5 40.3 32.9 33.8 36.6 39.3 32.1
33.0
35.7 38.4 30.5 31.4 34.0 36.4 28.2 29.1 31.5 33.8
S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.92
0.83
0.63 0.40 0.96 0.86 0.65 0.42 0.97 0.87 0.65 0.42
Delta T20181510201815102018151020
19
15 11 20 18 15 10 19 17 14 10
1350 KW 2.26 2.30 2.38 2.46 2.43 2.49 2.57 2.65 2.59 2.65 2.74 2.83 2.73
2.79
2.88 2.98 2.85 2.91 3.01 3.11 2.95 3.01 3.12 3.22
AMPS 7.9 8.1 8.4 8.7 8.6 8.8 9.0 9.4 9.3 9.5 9.8 10.2 9.9
10.2
10.5 10.9 10.6 10.8 11.2 11.6 11.2 11.5 11.8 12.3
HI PR 230 247 261 272 258 277 293 306 293 316 333 348 334
359
380 396 376 404 427 445 415 447 472 492
LO PR 108 115 125 134 114 121 132 141 119 126 138 147 124
132
145 154 130 139 152 161 135 144 157 167
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions KW=Total system power AMPS=outdoor unit amps (comp.+fan)