Amana ASX 14 SEER Air Conditioner User Manual


 
CONDENSING UNIT SPECIFICATIONS
6
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/
circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.
ASX140181A* - ASX140361A*
ASX140421A* - ASX140[48-60]1A* / ASX140[48-60]1B*
*
Up to 24' in equivalent line length
(1)
Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes.
(2)
Maximum Overcurrent Protection Device: MUST use Time Delay Fuses or HACR type Circuit Breaker of the same size as noted.
ASX140181A* ASX140241A* ASX140301A* ASX140361A*
Cooling Capacity, BTUH 18,000 24,000 30,000 36,000
Compressor
R.L. Amps 9.00 13.4 12.8 14.1
L.R. Amps 48.0 58.3 64.0 77.0
Low Pressure Switch
Open
Close
22 PSIG
50 PSIG
22 PSIG
50 PSIG
22 PSIG
50 PSIG
22 PSIG
50 PSIG
High Pressure Switch
Open
Close
610 PSIG
420 PSIG
610 PSIG
420 PSIG
610 PSIG
420 PSIG
610 PSIG
420 PSIG
Condenser Fan Motor
Horsepower 1/12 1/12 1/6 1/4
F.L. Amps 0.6 0.6 1.5 1.6
Liquid Line, Inches O.D.* 3/8" 3/8" 3/8" 3/8"
Suction Line, Inches O.D.* 3/4" 3/4" 3/4" 7/8"
Refrigerant Charge 121.0 126.0 131.0 146.0
Power Supply 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1
Minimum Circuit Ampacity
(1)
11.8 17.4 17.5 19.2
Maximum Overcurrent Device
(2)
20 30 30 30
Electrical Conduit Size
Power Supply (Inches) 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4
Approximate Shipping Weight 178 178 195 199
ASX140421A*
ASX140481
AA/AB/AC
ASX140481
AD/B
*
ASX140601A*
ASX140601B*
Cooling Capacity, BTUH 42,000 48,000 48,000 60,000
Compressor
R.L. Amps
17.9 19.8 19.8 26.4
L.R. Amps
112.0 109.0 109.0 134.0
Low Pressure Switch
Open
Close
22 PSIG
50 PSIG
22 PSIG
50 PSIG
22 PSIG
50 PSIG
22 PSIG
50 PSIG
High Pressure Switch
Open
Close
610 PSIG
420 PSIG
610 PSIG
420 PSIG
610 PSIG
420 PSIG
610 PSIG
420 PSIG
Condenser Fan Motor
Horsepower 1/4 1/4 1/4 1/4
F.L. Amps 1.6 1.6 1.6 1.6
Liquid Line, Inches O.D.* 3/8" 3/8" 3/8" 3/8"
Suction Line, Inches O.D.* 7/8" 7/8" 7/8" 7/8"
Refrigerant Charge
180.0 186.0 189.0 271.0
Power Supply 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1
Minimum Circuit Am
p
acit
y
(1)
24.0 26.4 26.4 34.6
Maximum Overcurrent Device
(2)
40 40 40 60
Electrical Conduit Size
Power Supply (Inches) 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4 1/2 or 3/4
Approximate Shipping Weight 207 242 242 280