Amana ASX 14 SEER Air Conditioner User Manual


 
13
COOLING PERFORMANCE DATA
ASX140241A*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
MODEL: ASX140241A* / CA*F3636B6A* / .057 Orifice
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67715963677159636771
MBh 23.5 24.4 26.7 - 23.0 23.8 26.1 - 22.4 23.2 25.5 - 21.9 22.7 24.8 - 20.8 21.5 23.6 - 19.3 20.0 21.9 -
S/T 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.70 0.48 - 0.84 0.70 0.49 -
Delta T 18 15 12 - 18 15 12 - 18 15 12 - 18 16 12 - 18 15 12 - 17 14 11 -
900 KW 1.63 1.66 1.71 - 1.75 1.78 1.84 - 1.85 1.89 1.95 - 1.94 1.98 2.04 - 2.02 2.06 2.13 - 2.09 2.13 2.20 -
AMPS 5.7 5.8 6.0 - 6.1 6.3 6.5 - 6.7 6.8 7.1 - 7.1 7.3 7.5 - 7.6 7.8 8.0 - 8.0 8.3 8.5 -
HI PR 242 260 264 - 273 294 298 - 311 334 339 - 354 381 386 - 398 428 434 - 446 480 486 -
LO PR 119 123 134 - 123 127 138 - 127 131 143 - 130 135 147 - 133 137 150 - 136 141 154 -
MBh 22.8 23.7 25.9 - 22.3 23.1 25.3 - 21.8 22.6 24.7 - 21.2 22.0 24.1 - 20.2 20.9 22.9 - 18.7 19.4 21.2 -
S/T 0.70 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.80 0.66 0.46 - 0.80 0.67 0.46 -
Delta T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
70 800 KW 1.62 1.65 1.70 - 1.74 1.77 1.82 - 1.84 1.87 1.93 - 1.93 1.97 2.03 - 2.00 2.05 2.11 - 2.07 2.11 2.18 -
AMPS 5.6 5.7 5.9 - 6.1 6.2 6.4 - 6.6 6.8 7.0 - 7.1 7.2 7.5 - 7.5 7.7 8.0 - 8.0 8.2 8.5 -
HI PR 239 257 261 - 271 291 295 - 308 331 336 - 350 377 382 - 394 424 430 - 442 475 482 -
LO PR 118 122 133 - 122 126 137 - 126 130 142 - 129 133 146 - 132 136 148 - 135 139 152 -
MBh 21.1 21.8 23.9 - 20.6 21.3 23.4 - 20.1 20.8 22.8 - 19.6 20.3 22.3 - 18.6 19.3 21.1 - 17.3 17.9 19.6 -
S/T 0.67 0.56 0.39 - 0.70 0.58 0.40 - 0.72 0.60 0.41 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.77 0.65 0.45 -
Delta T 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 18 15 12 -
700 KW 1.61 1.64 1.69 - 1.72 1.76 1.81 - 1.82 1.86 1.92 - 1.91 1.95 2.01 - 1.99 2.03 2.09 - 2.05 2.10 2.16 -
AMPS 5.6 5.7 5.9 - 6.0 6.2 6.4 - 6.5 6.7 6.9 - 7.0 7.2 7.4 - 7.5 7.6 7.9 - 7.9 8.1 8.4 -
HI PR 237 255 258 - 268 288 292 - 305 328 332 - 347 373 378 - 390 420 426 - 437 470 477 -
LO PR 117 121 132 - 120 124 136 - 125 129 140 - 128 132 144 - 130 135 147 - 134 138 151 -
MBh 23.9 24.6 26.7 28.6 23.4 24.1 26.0 27.9 22.8 23.5 25.4 27.3 22.2
22.9
24.8 26.6 21.1 21.8 23.6 25.3 19.6 20.2 21.8 23.4
S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.38 0.88 0.79 0.60 0.39 0.91
0.82
0.62 0.40 0.95 0.85 0.64 0.41 0.96 0.85 0.65 0.42
Delta T20191511211916112119161121
19
16 11 20 19 15 11 19 18 14 10
900 KW 1.63 1.66 1.71 1.76 1.75 1.78 1.84 1.89 1.85 1.89 1.95 2.01 1.94
1.98
2.04 2.11 2.02 2.06 2.13 2.19 2.09 2.13 2.20 2.27
AMPS 5.7 5.8 6.0 6.2 6.1 6.3 6.5 6.7 6.7 6.8 7.1 7.3 7.1
7.3
7.5 7.8 7.6 7.8 8.0 8.4 8.0 8.3 8.5 8.9
HI PR 242 260 264 269 273 294 298 305 311 334 339 346 354
381
386 394 398 428 434 444 446 480 486 497
LO PR 119 123 134 143 123 127 138 147 127 131 143 152 130
135
147 157 133 137 150 160 136 141 154 164
MBh 23.2 23.9 25.9 27.8 22.7 23.4 25.3 27.1 22.1 22.8 24.7 26.5 21.6
22.2
24.1 25.8 20.5 21.1 22.9 24.5 19.0 19.6 21.2 22.7
S/T 0.79 0.71 0.54 0.35 0.82 0.74 0.56 0.36 0.84 0.75 0.57 0.37 0.87
0.78
0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.82 0.62 0.40
Delta T21201611212016112120161122
20
16 11 21 20 16 11 20 18 15 10
75 800 KW 1.62 1.65 1.70 1.75 1.74 1.77 1.82 1.88 1.84 1.87 1.93 1.99 1.93
1.97
2.03 2.09 2.00 2.05 2.11 2.18 2.07 2.11 2.18 2.25
AMPS 5.6 5.7 5.9 6.2 6.1 6.2 6.4 6.7 6.6 6.8 7.0 7.3 7.1
7.2
7.5 7.8 7.5 7.7 8.0 8.3 8.0 8.2 8.5 8.8
HI PR 239 257 261 267 271 291 295 302 308 331 336 343 350
377
382 391 394 424 430 439 442 475 482 492
LO PR 118 122 133 142 122 126 137 146 126 130 142 151 129
133
146 155 132 136 148 158 135 139 152 162
MBh 21.4 22.1 23.9 25.6 20.9 21.6 23.3 25.0 20.4 21.0 22.8 24.4 19.9
20.5
22.2 23.8 18.9 19.5 21.1 22.7 17.5 18.1 19.6 21.0
S/T 0.77 0.68 0.52 0.33 0.79 0.71 0.54 0.35 0.81 0.73 0.55 0.35 0.84
0.75
0.57 0.37 0.87 0.78 0.59 0.38 0.88 0.79 0.59 0.38
Delta T22201611222016112220161122
20
17 11 22 20 16 11 20 19 15 11
700 KW 1.61 1.64 1.69 1.74 1.72 1.76 1.81 1.86 1.82 1.86 1.92 1.98 1.91
1.95
2.01 2.07 1.99 2.03 2.09 2.16 2.05 2.10 2.16 2.23
AMPS 5.6 5.7 5.9 6.1 6.0 6.2 6.4 6.6 6.5 6.7 6.9 7.2 7.0
7.2
7.4 7.7 7.5 7.6 7.9 8.2 7.9 8.1 8.4 8.7
HI PR 237 255 258 264 268 288 292 298 305 328 332 339 347
373
378 387 390 420 426 435 437 470 477 487
LO PR 117 121 132 140 120 124 136 145 125 129 140 149 128
132
144 153 130 135 147 156 134 138 151 160
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions