Nilfisk-ALTO SR 1450 B-D Vacuum Cleaner User Manual


 
USER MANUAL
33014811(1)2005-07 A 17
PERIODICAL CHECKS
Battery (SR 1450 D)
Check the electrolyte level.
Check the battery poles for oxidation.
Clean the entire surface of the battery with a damp sponge.
Tyre pressure
Recommended pressure: 7 Bar
Fluid levels
Brake fluid: DOT4
Hydraulic oil (SR 1450 D): AGIP Arnica 46
Hydraulic oil (SR 1450 B): Rotra ATF
Engine oil: AGIP Sigma
(HD series 3 MIL - L 2104-C
API - CD)
Coolant level (SR 1450 D)
Mixture: 50% AGIP antifreeze and 50% water
Skirt closing adjustment
Loosen the locknut (1, Fig. L).
Adjust the fastener, making sure that the skirt closing
panel closes hermetically.
Adjust the skirt spring (2, Fig. L) pressure with the
mounting nut.
Carbon
brushes
Check the carbon brush for wear. It is worn out
when more than half of its total length has been
consumed. Check that it slides freely in the brush
holder, that it is pressed correctly by the spring and
that the spring is still elastic.
Ensure that the surface along which the carbon
brushes slide is evenly and highly polished and
that any lines or porosity are extremely small and
of similar dimensions.
Check the wire for wear and ensure that the
connection terminals are well tightened.
Ensure that there are no big lines, deep grooves,
craters, burns or splinters on the carbon brush
edge and that all the carbon brushes are worn in
the same way.
Check the housing for wear and clearance.
Brushes usually last from 6 months to 1 year,
depending on use.
Check the carbon brush and coupling pressure.
When the warning light turns on, the carbon
brushes need to be replaced, even if 300 hours
have not been reached.
Terminals Check that supply bolt nuts are well tightened and
that the insulating materials are in good condition.
Fan Ensure that air intakes are not clogged and that the
fan turns freely.
Bearings Check the temperature and the vibration and noise
degree.
Insulation Use a megger, especially when the environment is
wet, to check the insulation value: it should never
be less than 2 MOhm.
Screws Check that the screws are not loose.
Check that there are no faulty contacts in the
electrical connections which could lead to local
overheating.
Windings General cleaning. Check that the insulation to
ground is less than 2 MOhm.
Maintenance
Every 150
hours
Every 200
hours
Every 400
hours
Every 6
months
Every
year
Every time
a check is
carried out
WARNING!
Wear gloves and goggles.