Nilfisk-ALTO 46/53 Vacuum Cleaner User Manual


 
1-30 American-Lincoln
ATS 46-53 Battery
THE RECOVERY OR ESP AND AUTOFIL SYSTEM - HOW IT WORKS
During the scrubbing process, filtered water from the solution tank is fed to the solution line, where it combines
with detergent from the metering pump. This mixture is then fed to the floor where three disc scrubbing brushes
work to dislodge soil.
After scrubbing, the dirty solution is vacuumed from the floor and discharged into the recovery tank. At inter-
vals, a float switch activates the recycling pump, which sends filtered solution from the recovery tank to the
solution tank. Detergent is added continuously to solution water from the flow valve.
The autofil system distributes water from the supply hose into the recovery and solution tanks. Then a solenoid
valve is closed when the proper level in the solution tank is reached.
NOTE
Both tanks must be drained and cleaned before filling.
Tuck solution tank drain hose behind bumper during operation hose
ESP SYSTEM OPERATING INSTRUCTIONS
SOLUTION
TANK
RECOVERY
TANK
FILTER
FLOW VALVE
ORIFICE
VALVE
CHECK
VALVE
SCRUB
BRUSH
SQUEEGEE
FILL COUPLING
AUTOFIL
FLOOR CONTACT
FILTER
SOLUTION
PUMP
SEPARATOR
DETERGENT
PUMP
DETERGENT
TANK
P4759a
P4759A FIGURE 33