Allstar Products Group MVP-SQ Garage Door Opener User Manual


 
NEVER LET CHILDREN OPERATE OR
PLAY WITH DOOR CONTROLS. KEEP THE
REMOTE CONTROL AWAY FROM
CHILDREN.
ALWAYS KEEP A MOVING DOOR IN SIGHT
AND KEEP PEOPLE AND OBJECTS AWAY
FROM THE DOOR AREA UNTIL THE DOOR
IS COMPLETELY CLOSED. NO ONE
SHOULD CROSS THE PATH OF A MOVING
DOOR.
NEVER GO UNDER A STOPPED,
PARTIALLY OPEN DOOR.
TEST THE DOOR OPENER MONTHLY. THE
DOOR MUST REVERSE UPON CONTACT
WITH A 1-1/2” HIGH OBJECT (OR A 2 X 4
BOARD LAID FLAT) ON THE FLOOR.
AFTER ADJUSTING THE SENSITIVITY OR
THE LIMIT OF TRAVEL, ALWAYS RETEST
THE OPENER. FAILURE TO ADJUST THE
OPENER PROPERLY MAY RESULT IN
SERIOUS INJURY OR DEATH.
IF POSSIBLE, USE THE EMERGENCY
RELEASE ONLY WHEN THE DOOR IS
CLOSED. USE CAUTION WHEN USING
THE RELEASE WITH THE DOOR OPEN.
WEAK OR BROKEN SPRINGS MAY ALLOW
THE DOOR TO CLOSE RAPIDLY, CAUSING
SEVERE INJURY OR DEATH.
KEEP THE GARAGE DOOR PROPERLY
BALANCED. SEE THE DOOR OWNER'S
MANUAL. AN IMPROPERLY BALANCED
DOOR MAY CAUSE SEVERE INJURY OR
DEATH. HAVE A QUALIFIED SERVICE
PERSON MAKE REPAIRS TO CABLES,
SPRING ASSEMBLIES AND OTHER
HARDWARE.
SAVE THESE INSTRUCTIONS!
WARNING! TO REDUCE THE
RISK OF SEVERE INJURY OR DEATH
READ AND FOLLOW ALL INSTRUCTIONS!
IMPORTANT SAFETY INSTRUCTIONS
TURNING ON POWER TO THE
OPENER
NOTE: It is now necessary to turn on the
power in order to run the opener to test the
operation and check the limit settings. Before
doing so, ensure that all mounting hardware is
installed and has been properly tightened, that
all electrical connections are per local code
requirements, and that proper wiring practices
have been followed. Also, double-check that
all ropes have been removed from the door
and that the doorway is clear.
BASIC OPERATING PARAMETERS
Please note the following Operating Parameters which
apply to Openers with Auxiliary Entrapment
Protection System (Safe Finish™ Photosystem,
Installation Instructions on Page 15) and a standard
wall push button connected. Please see page 17 for
instructions concerning the Super Station Deluxe Wall
Push Button operating parameters.
IF THE DOOR IS…
...FULLY OPEN, then pushing the standard wall Push
Button or the radio control will cause the door to begin
MOVING DOWNWARD.
...FULLY CLOSED, then pushing the wall Push
Button or the radio control will cause the door to begin
MOVING UPWARD.
...MOVING UPWARD, then pushing the wall Push
Button will cause the door to STOP. The next push
of the wall button will cause the door to begin
MOVING DOWNWARD (Alternate Action
Operation).
...MOVING UPWARD, then pushing the radio
control will cause the door to STOP. The next push
of the wall button will cause the door to RESUME
UPWARD MOVEMENT (Radio Operation).
...MOVING DOWNWARD, then pushing the wall
Push Button or the radio control will cause the door to
STOP, PAUSE FOR APPROXIMATELY ONE
SECOND, AND THEN BEGIN MOVING
UPWARD.
...MOVING DOWNWARD then reaches the down
limit, the lamp will blink off for a 1/2 second then turn
back on again, remaining on for 4 minutes 30 seconds
and will then automatically turn off.
...MOVING UPWARD then reaches the open limit,
the lamp will remain on for 4 minutes 30 seconds and
will then automatically turn off.
OPERATION AND ADJUSTMENT INSTRUCTIONS
15