[2] Auto-arm Control
Pressing [2] while in the User Function menu will enable (3 beeps) or disable (one long beep) the Auto-arm fea-
ture, by partition. With this feature enabled, the panel will automatically arm in the Away mode (Stay Away zones
active) at the same time each day. The auto-arm time is programmed with the [✱][6][Master Code][3] command.
[3] Auto-arm Time
The system can be programmed to arm at a programmed time each day, per partition.
Upon entry of this section, enter 4 digits for the 24-hour Auto-arm time for each day of the week.
At the selected auto-arm time, the keypad buzzers will sound for a programmed amount of time (programmable
by the installer only) to warn that an auto-arm is in progress. The bell can also be programmed to squawk once
every 10 seconds during this warning period. When the warning period is complete, the system will arm with no
exit delay and in the Away Mode.
Auto-arming can be cancelled or postponed by entering a valid access code only, during the programmed warn-
ing period. Auto-arming will be attempted at the same time the next day. When the auto-arming process is can-
celled or postponed, the Auto-arm Cancellation Reporting Code will be transmitted (if programmed).
If arming is inhibited by one of the following, the Auto-arm Cancellation transmission will be communicated.
- AC / DC Inhibit Arm
- Latching System Tampers
- Zone Expander Supervisory Fault
[4] System Test
The system’s Bell Output (2s), Keypad Lights and Communicator are tested. This test will also measure the panel’s
standby battery.
[5] Enable DLS / Allow System Service
If enabled, the installer will be able to access Installer Programming by DLS. In case of DLS access this provides a
window where rings will be detected by the panel. The DLS window will remain open for 6hrs, during which time
the installer will be able to enter DLS an unlimited number of times. After the 6-hr window has expired, Installer’s
Programming will be unavailable again until the window is re-opened.
[6] User Call-up
If enabled by the Installer, the panel will make 1 attempt to call the downloading computer. The downloading
computer must be waiting for the panel to call before downloading can be performed.
[7] Music Input On/Off
If enabled on the PC5936 Audio Interface Module, the user can turn Background Music on or off.
[8] User Walk Test (For Europe only)
This test allows the user to verify operation of system detectors and notifies the central station that a Walk Test is
in progress.
Note: Fire zones, the 'F' key, and 2-wire Smoke detectors are excluded from this test. Violation of these zones will
cause the system to exit the walk test then generate and transmit alarm condition to the central station.
1. Press to enable Walk Test. The system will notify the Central Station that a walk test has begun.
2. Violate all each detector (zone) in sequence. A squawk will occur at the keypad and the violation will be
recorded in the Event Buffer.
3. Restore zones. Press to end the Walk Test. The system will notify the Central Station that the walk
test has been terminated.
Note: If a zone is not violated within 15 minutes of activating the Walk Test, the system will automatically exit the
Walk Test and resume normal operation.