![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/5/50/5509b07a-e776-456e-8d3d-6a841cf7b3ae/5509b07a-e776-456e-8d3d-6a841cf7b3ae-bg4c.png)
B-4
1600XP Series Installation and Operation Manual
1600XP Command Parameters Table
Cmd
ID
Description
on LCD
Brief Description Location Map Example
Rqd Security
Level to change
By
Tab Block
222 VOOV De-
Level*
Output Overvoltage Detection Level in percent-
age
- Of rated output voltage which was congured
with Command ID215
Setting OUT 110 % Nonchangeable
Nonchangeable
Changeable
User
Administrator
Service
224 Fo Syn Win-
dow*
Output Frequency Synchronization Window Setting OUT 1.0 Hz Nonchangeable
Nonchangeable
Changeable
User
Administrator
Service
225 Fo Slew Rate Output Frequency Slew Rate Setting OUT 10 Changeable Service
226 Vout Adjust Output Voltage Adjustment
- Can adjust up to +/- 5 increment of one in
order to increase or decrease output voltage to
compensate line voltage drop.
Setting OUT 0 Nonchangeable
Changeable
Changeable
User
Administrator
Service
227 Iout 100%
Amount
Output Current 100% Amount Setting OUT 250 Changeable Service
228 OOL Delevel Output Overload Warning/Fault Detection Level
in percentage
Setting OUT 110 Changeable Service
229 OOL DeDelay Output Overload Warning/Fault Detection De-
lay at 125% @25°
Setting OUT 30 Changeable Service
230 OOL ReLevel Output Overload Warning Recovery Delay Setting OUT 105 Changeable Service
231 OOL ReDelay Output Overload Warning Recovery Delay Setting OUT 160 Changeable Service
232 Vout Comp.
Step
Output Voltage will be compensated according
to this setup and current percentage
Setting OUT 20 Changeable Service
233 Vout Gain Use this value to convert AD value to Actual
Value
Setting OUT 7987 Changeable Service
234 Vout Offset Feedback Offset adjustment due to hardware
and software components
Setting OUT 0 Changeable Service
242 Iout Gain At 240VAC use this value to convert AD VAlue
to Actual Value
Setting OUT 1131 Changeable Service
243 Iout Offset Feedback Offset adjustment due to hardware
and software compenents.
Setting OUT 0 Changeable Service
251 Vref PhAdj
60Hz
Time delay adjustment to sync the actual phase
of output and plotting.
Setting OUT -8 Changeable Service
254 Vref Amplitude Calibrated no Load Output Voltage Setting OUT 246 Changeable Service