A SERVICE OF

logo

Page 40 Section 5 Maintenance
MSD SABER SERIES SHEARS
CYLINDER GAP CHECK
Periodically check (minimum once per week) the gap between the rod eye shoulder and head face (X) with
the cylinder fully retracted (see Figure 5-43). If the gap exceeds the dimensions given in the table, below, by
more than .06", it could be an early indication of required maintenance. Stop shear operations and call the
LaBounty Service Department: (218)-834-6901.
MODEL X-DIMENSION
1500 0.50"
2000 1.50"
2500 0.50"
3000 0.50"
4000 0.50”
4500 1.00"
7500 0.75"
9500 0.75"
FIGURE 5-43
X