6.11 High Speed Zone Compare
Table Comparison Flags
(M8130 to M8139 and D8130 to D8139)
For symbol key see pa
e 6-1
Diagnostic
Device
Operation
Diagnostic
Device
Operation
M8130
Selects comparison tables
to be used with the HSZ
instruction
D8130 (
)( )
Contains the number of the
current record bein
pro-
cessed in the HSZ compari-
son table
M8131 (
)( )
Identifies when the HSZ
comparison table has been
processed.
D8131 (
)( )
Contains the number of the
current record bein
pro-
cessed in the HSZ compari-
son table when the PLSY
operation has been enabled
M8132
Selects the use of the PLSY
instruction with the HSZ
comparison tables
D8132 (
)( )
Contains the source (output
pulse frequenc
) data for the
PLSY instruction when used
with the HSZ comparison
table
M8133 (
)( )
Identifies when the HSZ
comparison table (when
used with the PLSY instruc-
tion) has been processed.
D8133 Reserved
M8134-
M8139
Reserved
D8134
D8135
(
) ( )
Contains a cop
of the value
for the current comparison
when the HSZ comparison
table and combined PLSY out-
put are used. This data is onl
available in 32 bit or double
word format.
D8136
D8137
(
) ( )
Contains the total number of
pulses that have been output
usin
the PLSY (or PLSR)
instruction. This data is onl
available in 32 bit or double
word format
D8138 -
D8139
Reserved
D8140
D8141
(
) ( )
(FX
2N(C)
only)
Contains the total number of
pulses that have been output
to Y0 usin
the PLSY or PLSR
instructions. This data is onl
available in 32 bit or double
word format.
D8142
D8143
(
) ( )
(FX
2N(C)
only)
Contains the total number of
pulses that have been output
to Y1 usin
the PLSY or PLSR
instructions. This data is onl
available in 32 bit or double