![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/b/24/b249deaf-1fd7-4d91-a629-3b60b4c6e920/b249deaf-1fd7-4d91-a629-3b60b4c6e920-bg9d.png)
155
Selection of operation mode and operation location
4
PARAMETERS
4.15.2 Setting the speed by the operation panel
POINT
Use the operation panel to give a start command and a speed command. (PU operation)
Operation
example
Operate at 900r/min.
Operation Display
1.
Screen at power-ON
The monitor display appears.
2. Change the Pr. 79 setting to "1".
(Refer to page 50 for change of the setting.)
PU indicator is lit.
3. Turn to show the speed you want to set.
The speed flickers for about 5s.
4. While the value is flickering, press to set
the speed.
(If is not pressed, the indication of the
value goes back to " " (0r/min) after about 5s
of flickering. In that case, go back to "operation
step 3" and set the speed again.)
After about 3s of flickering, the indication of the
value goes back to " " (monitor display).
Flicker...speed setting complete!!
The monitor display appears after 3s.
5. Start acceleration constant speed
Press to start operation.
The speed value on the indication increases in
Pr. 7 Acceleration time, and " " (900r/min)
appears.
6. To change the set speed, perform the operation in above steps 3 and 4. (Starting from the previously set speed.)
7. Deceleration stop
Press to stop.
The speed value on the indication decreases in
Pr. 8 Deceleration time, and the motor stops
rotating with " " (0r/min) displayed.
Operation panel
Flickers for about 5s
Stop