9. Pass the gasket (8), flat washer (7) and fixing gland (11) through the transducer cable.
10.Fasten the fixing gland (11) to the top of the shaft (6).
The height between the top of the fixing gland (11) and the top of the shaft (6) must be less
than 7 mm.
11.Apply grease (supplied) to both sides of the gasket 1 (5), and set it on the spacer (3).
12.Apply grease (supplied) to the inside of the spacer (3).
13.Clean the top and bottom of the gate valve (2), and mount it on the gasket 1 (5) mounted on
the spacer (3) at step 11.
Gasket (8)
Washer (7)
The hollow side must be downward.
Fixing gland (11)
Seal washer (27)
Hex. bolt (26)
Transducer (1)
Shaft (6)
Transducer cable