1. INSTALLATION
1-8
9. Use M16 nut (11), spring washer (12) and flat washer (13) to fix the transducer (1) w/fixing
plate to the fixing flange (4).
10.For the transducer DS-631, do the following steps:
1) Attach the grommet (supplied) to the location marked with a white line on the transducer
cable.
2) Fix the grommet attached at step 1) to the notch shown below, by using the cable fixing
plate (17), hex. bolt M6x12 (18), spring washer M6 (19).
3) Pass the connector at the end of the transducer cable between the transducer and M16
bolt, and attach the notch as shown below.
4) Connect the cable assy. (supplied) to the connector attached at step 3).
Clean the connector faces and pins before the connection.
Transducer (1)
Fixing flange (4)
Fixing plate (5)
Hex. bolt (15)
Seal washer (16)
M16 hex. nut (11)
M16 spring
washer (12)
M16 flat
washer (13)
Transducer cable
Attach the connector to this notch.
Pass the cable between
the transducer and this bolt.
Grommet
Cable fixing plate (17)
M6 spring washer (19)
Hex. bolt M6x12 (18)
Notch
(for grommet)
White mark