Check Cabinet Wiring
© 2006 GLOBAL VR, INC.
040-0068-01 Rev B 1/12/2006 Page 5 of 14
3. Refer to Figure 2 and inspect the power plate to make sure that the correct color wire is connected to
each connector.
Figure 2. Power Plate Connections
4. Inspect your cabinet to see if there is a ground wire from the ground lug on the EMI filter to the
ground lug on the coin vault. If the wire is present, make sure it is tightly connected. Otherwise,
perform the following steps to install a ground wire.
a. Install a 2 1/2' ground wire to the lug on the right of the EMI filter, as shown in Figure 2. Use a
#8-32 kep nut to secure it in place. Secure the nut tightly.
b. Connect the other end of the wire to the ground lug on the coin vault (coin box). Use a #8-32
kep nut to connect the ground wire on top of the other ground wires, as shown in Figure 3.
Secure the nut tightly.
c. Confirm the following wires are connected to the coin vault ground lug:
One wire from coin vault to coin door
One wire from coin vault to trackball
Important: All ground wires must be secured tightly!
Figure 3. Coin Vault Ground Lug