www.desatech.com
119304-01A22
6. In case any large clumps of dust have now
been pushed into the burner repeat steps 3 and
4, page 21.
Clean the pilot assembly also. A yellow tip on the
pilot ame indicates dust and dirt in the pilot as-
sembly. There is a small pilot air inlet hole about
2" from where the pilot ame comes out of the
pilot assembly (see Figure 38). With the unit off,
lightly blow air through the air inlet hole. You may
blow through a drinking straw if compressed air
is not available.
LOGS
• If you remove logs for cleaning, refer to Install-
ing Logs, page 16, to properly replace logs.
• Replace log(s) if broken or chipped (dime-sized
or larger).
Figure 38 - Pilot Inlet Air Hole
Burner
Tube
Pilot
Assembly
Pilot Air
Inlet Hole
Ports/
Slots
CLEANING AND
MAINTENANCE
Continued
WIRING DIAGRAM
Note: For proper operation of optional accessories,
the wires from the switch to the control must be
connected exactly as shown.
SPECIFICATIONS
• Rating (Variable) 21,500/33,000 Btu/Hr
• Type Gas Natural Gas Only
• Ignition Piezo
• Pressure Manifold 3.5" W.C.
• Inlet Gas Pressure (in. of water)
Maximum 10.5"
Minimum* 5"
• Shipping Weight 122 lbs.
* For input adjustment
• Rating (Variable) 21,500/33,000 Btu/Hr
• Type Gas Propant/LP Only
• Ignition Piezo
• Pressure Manifold 7.9" W.C.
• Inlet Gas Pressure (in. of water)
Maximum 13"
Minimum* 11"
• Shipping Weight 122 lbs.