York YMA024 Heat Pump User Manual


 
036-21570-002 Rev. D (0605)
4 Unitary Products Group
** Refer to Quick Selection Chart for specific furnace match-up.
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR HANDLER
COIL
1
MODEL
COOLING
MODEL
ELECTRIC
2
HEAT KW
W
RATED
CFM
TOTAL
CAPACITY
SENSIBLE
CAPACITY
SEER
W/O TXV
SEER
W/ TXV
EER
1 PH 12 SEER HP WITH N1AH / G2FD
YMA02411
N1AHB08 2,5,8,10 17 G2FD030(S,H)17(T) 800 24.0 18.8 12.00 12.00 10.90
N1AHB12 2,5,8,10 17 G2FD030(S,H)17(T) 800 24.0 18.8 12.00 12.00 10.90
YMA03011
N1AHB08 2,5,8,10 17 G2FD030(S,H)17(T) 1000 30.0 23.0 12.00 12.00 11.10
N1AHB12 2,5,8,10 17 G2FD030(S,H)17(T) 1000 30.0 23.0 12.00 12.00 11.10
N1AHB08 2,5,8,10 17 G2FD036(S,H)17(T) 1200 35.2 27.2 12.00 12.00 11.05
YMA03611
N1AHB12 2,5,8,10 17 G2FD036(S,H)17(T) 1200 35.2 27.2 12.00 12.00 11.05
N1AHC16 5,8,10,15,20 21 G2FD036(S,H)21(T) 1200 35.6 28.0 12.00 12.00 11.30
YMA04211
N1AHC16 5,8,10,15,20 21 G2FD048(S,H)21(T) 1400 42.0 32.8 12.00 12.00 10.70
N1AHD20 8,10,15,20,25,30 24 G2FD048(S,H)24(T) 1400 42.0 32.8 12.00 12.00 10.70
YMA04811
N1AHD20 8,10,15,20,25,30 24 G2FD060(S,H)24(T) 1600 46.0 35.6 - 12.00 10.20
N1AHD20 8,10,15,20,25,30 24 G2FD061H24 1600 46.0 36.0 - 12.00 10.25
YMA06011
N1AHD20 8,10,15,20,25,30 24 G2FD060(S,H)24(T) 1800 54.0 42.2 11.70 - 10.50
N1AHD20 8,10,15,20,25,30 24 G2FD061H24 1800 54.5 42.4 12.00 - 10.55
1 PH 12 SEER HP / N1VS - VARIABLE SPEED
YMA02411 N1VSB12 2,5,8,10 17 G2FD030(S,H)17(T) 775 24.2 18.5 13.00 13.00 11.95
YMA03011 N1VSB12 2,5,8,10 17 G2FD030(S,H)17(T) 1000 30.2 22.8 13.00 13.00 11.95
YMA03611
N1VSB12 2,5,8,10 17 G2FD036(S,H)17(T) 1200 35.4 26.8 12.50 12.50 11.65
N1VSC16 5,8,10,15,20 21 G2FD036(S,H)21(T) 1200 36.0 27.6 13.00 13.00 12.20
YMA04211
N1VSC16 5,8,10,15,20 21 G2FD048(S,H)21(T) 1380 42.5 32.4 13.00 13.00 11.45
N1VSD20 8,10,15,20,25,30 24 G2FD048(S,H)24(T) 1350 42.5 32.0 13.00 13.00 11.40
YMA04811
N1VSD20 8,10,15,20,25,30 24 G2FD060(S,H)24(T) 1600 46.0 35.0 - 12.50 10.65
N1VSD20 8,10,15,20,25,30 24 G2FD061H24 1600 46.5 35.4 - 12.50 10.70
YMA06011
N1VSD20 8,10,15,20,25,30 24 G2FD060(S,H)24 1780 53.5 40.6 12.00 - 10.65
N1VSD20 8,10,15,20,25,3 24 G2FD061H24 1780 54.5 41.4 12.10 - 10.85
1 PH 12 SEER HP / F2RP / RC / FP / FC / FV
3,4
YMA02411
F2RC/F2FC036 5,8,10,15 18 - 800 24.0 18.8 12.00 12.00 10.90
F2RP/F2FP/F3FP024 5,8,10,15 18 - 800 23.6 18.6 12.00 12.00 10.90
F2RP/F2FP/F3FP030 5,8,10,15 18 - 800 24.0 18.8 12.00 12.00 10.90
YMA03011
F2RC/F2FC036 5,8,10,15 21 - 1000 29.6 22.2 12.00 12.00 11.05
F2RP/F2FP/F3FP030 5,8,10,15 21 - 1000 29.6 22.2 12.00 12.00 11.05
F2FP/F3FP040 5,8,10,15 21 - 1200 36.0 27.2 12.00 12.00 11.30
YMA03611
F2RP/F2FP/F3FP036 5,8,10,15 21 - 1200 35.8 27.0 12.00 12.00 11.20
F2RP/F2FP/F3FP042 5,8,10,15 21 - 1200 36.0 27.2 12.00 12.00 11.30
YMA04211
F2FP048 5,8,10,15,20,25 24 - 1400 41.5 31.8 12.00 12.00 10.55
F2FP/F3FP060 8,10,15,20,25 24 - 1600 45.5 34.2 - 11.50 10.00
YMA04811 F2FP045 5,8,10,15 24 - 1600 45.5 34.5 - 12.00 10.20
YMA06011
F2FP060 8,10,15,20,25 24 - 1800 53.0 40.4 11.25 - 10.25
F2FV060 8,10,15,20,25 24 - 1780 54.0 40.8 12.00 - 10.75
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1 G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2 Single phase units require single phase 2HK heaters.
3 To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC
. models. All ratings remain the same.
4 FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D. standard.