York YHJD18 Heat Pump User Manual


 
397855-YTG-G-0509
32 Johnson Controls Unitary Products
Multipliers for determining the performance with other indoor sections.
Continued on next page.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO YHJD42S41S1
EVAPORATOR COIL MODEL NO FC/MC/PC/UC48
AIR TEMP.
ENTERING
OUTDOOR UNIT
AIR TEMP.
ENTERING
INDOOR COIL
ID CFM
1200 1400 1600
MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P.
60
60 48.7 3.5 4.1 48.7 3.5 4.1 48.7 3.4 4.2
70 47.8 3.8 3.6 48.6 3.8 3.7 49.5 3.8 3.8
80 46.8 4.2 3.3 48.6 4.2 3.4 50.3 4.1 3.6
47
60 42.5 3.3 3.8 42.9 3.3 3.8 43.3 3.2 3.9
70 42.3 3.6 3.4 42.7 3.6 3.5 43.1 3.6 3.6
80 42.0 3.9 3.1 42.4 3.9 3.2 42.9 3.9 3.3
40
60 40.1 3.2 3.7 40.5 3.2 3.7 40.8 3.2 3.8
70 39.1 3.5 3.3 39.6 3.5 3.3 40.0 3.5 3.4
80 38.2 3.8 2.9 38.7 3.8 3.0 39.2 3.8 3.0
30
60 33.5 3.8 2.6 33.8 3.7 2.7 34.1 3.7 2.7
70 34.8 3.4 3.0 34.5 3.4 3.0 34.1 3.4 2.9
80 36.2 3.1 3.4 35.1 3.1 3.3 34.1 3.1 3.2
17
60 27.8 3.6 2.2 28.4 3.6 2.3 29.1 3.6 2.4
70 28.3 3.3 2.5 28.8 3.3 2.5 29.2 3.3 2.6
80 28.8 3.0 2.8 29.1 3.0 2.8 29.4 3.0 2.8
10
60 26.3 3.6 2.1 26.9 3.6 2.2 27.6 3.6 2.2
70 25.6 3.3 2.3 26.8 3.3 2.4 28.0 3.3 2.5
80 24.8 3.0 2.4 26.6 3.0 2.6 28.4 3.0 2.8
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handlers Coils MBH KW COP
FC/MC/PC60 1.00 1.06 0.94
HC42 0.99 0.99 1.00
HC60 1.00 1.06 0.94
HD60 0.99 0.89 1.11
AHP/SHP48 1.00 1.00 1.00
AHX42 0.98 1.05 0.93
AHX48 0.98 1.07 0.92
AV/SV*48 0.98 1.05 0.94
F4FP045 1.01 1.07 0.94
F5FP048 0.99 1.01 0.98
F6FP042 0.99 1.06 0.94
F6FP048 0.99 1.09 0.91
MA14D FC/MC/PC48D 1.00 1.00 1.00
MA16C FC/MC/PC48C 1.00 1.00 1.00
MV16C FC/MC/PC48C 0.99 0.99 1.00
MV20D FC/MC/PC48D 0.98 0.98 1.00
MA14D FC/MC/PC60D 1.00 1.06 0.94
MA16C FC/MC/PC60C 1.00 1.06 0.94
MV20D FC/MC/PC60D 0.98 1.04 0.94