York YHJD18 Heat Pump User Manual


 
Johnson Controls Unitary Products 27
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
CONDENSING UNIT MODEL NO. YHJD60S41S1
INDOOR COIL MODEL NO. FC/MC62
CONDENSING
ENTERING AIR
TEMPERATURE
IDCFM 1600 1800 2000
ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80
ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
65
T.C. 54.0 57.1 56.9 62.3 67.6 56.0 57.9 57.8 63.4 69.1 58.0 58.7 58.7 64.4 70.5
S.C. 54.0 51.0 43.4 42.9 34.8 56.0 54.4 45.4 45.0 36.2 58.0 57.7 47.4 47.1 37.6
KW 2.8 2.8 2.8 2.9 2.9 2.8 2.8 2.8 2.9 2.9 2.8 2.8 2.8 2.9 2.9
75
T.C. 51.9 54.1 53.9 59.2 64.5 53.7 54.9 54.8 60.2 65.7 55.5 55.7 55.6 61.2 66.9
S.C. 51.9 49.8 42.0 41.7 33.5 53.7 52.7 44.1 43.8 34.8 55.5 55.6 46.1 45.8 36.2
KW 3.2 3.2 3.2 3.3 3.3 3.2 3.2 3.2 3.3 3.3 3.2 3.2 3.2 3.3 3.3
85
T.C. 49.7 51.1 51.0 56.2 61.4 51.3 51.9 51.8 57.1 62.4 53.0 52.7 52.6 58.0 63.4
S.C. 49.7 48.6 40.7 40.5 32.2 51.3 51.1 42.8 42.5 33.4 53.0 52.7 44.9 44.6 34.7
KW 3.6 3.6 3.6 3.6 3.7 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.7 3.7
95
T.C. 47.6 48.1 48.1 53.1 58.3 49.0 48.9 48.8 54.0 59.0 50.4 49.7 49.5 54.8 59.8
S.C. 47.6 47.4 39.3 39.2 30.9 49.0 48.9 41.5 41.3 32.0 50.4 49.7 43.6 43.3 33.2
KW 4.0 4.0 4.0 4.0 4.1 4.0 4.0 4.0 4.1 4.1 4.0 4.0 4.0 4.1 4.1
105
T.C. 44.3 44.6 44.1 48.7 53.5 45.6 45.5 44.6 49.3 54.1 46.8 46.3 45.2 50.0 54.7
S.C. 44.3 44.6 37.6 37.4 29.0 45.6 45.5 39.7 39.4 30.2 46.8 46.3 41.8 41.5 31.3
KW 4.5 4.5 4.5 4.5 4.6 4.5 4.5 4.5 4.5 4.6 4.5 4.5 4.5 4.5 4.6
115
T.C. 41.1 41.3 40.2 44.4 48.9 42.2 42.2 40.6 44.9 49.4 43.3 43.1 41.0 45.3 49.9
S.C. 41.1 41.3 35.9 35.7 27.3 42.2 42.2 37.9 37.7 28.4 43.3 43.1 40.0 39.7 29.5
KW 4.9 5.0 4.9 5.0 5.0 5.0 5.0 4.9 5.0 5.0 5.0 5.0 5.0 5.0 5.0
125
T.C. 37.9 37.9 36.2 40.1 44.3 38.8 38.8 36.5 40.4 44.6 39.8 39.8 36.8 40.7 45.0
S.C. 37.9 37.9 34.2 33.9 25.5 38.8 38.8 36.2 35.9 26.6 39.8 39.8 36.8 37.9 27.7
KW 5.4 5.4 5.4 5.4 5.5 5.4 5.4 5.4 5.4 5.5 5.4 5.4 5.4 5.4 5.5
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handlers Coils T.C. S.C. KW
AHX60 1.06 1.13 1.05
F6FP060 1.06 1.09 1.01
MA20D MC62D 1.00 1.00 1.00
MV20D MC62D 1.01 1.01 1.00
Furnaces Coils T.C. S.C. KW
T*(8,L)X*C20 FC/MC62D 1.05 1.08 0.99
T*9X*D20 FC/MC62D 1.02 1.02 1.02
(Y*9C/T*9V)*D20 FC/MC/PC60D 0.99 0.96 0.97
Y*(8,L)C*C20 FC/MC62D 1.00 0.97 0.96
(Y*9C/T*9V)*C20 FC/MC62D 0.99 0.96 0.98