York YHJD18 Heat Pump User Manual


 
Johnson Controls Unitary Products 17
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
YHJD48S41S1
T*(8,L)X*C16 FC/PC60C 47.0 3.46 3.98 32.8 2.28 4.22 8.00
T*9X*C16 FC/PC60C 47.0 3.46 3.98 32.8 2.28 4.22 8.00
T*(8,L)X*C20 FC/MC/PC60D 47.0 3.48 3.96 32.8 2.28 4.22 8.00
T*9X*C20 FC/PC60C 47.0 3.48 3.96 32.6 2.30 4.15 8.00
T*9X*D20 FC/MC/PC60D 46.5 3.50 3.89 32.2 2.32 4.07 8.10
T*9X*D20 FC/MC62D 47.5 3.54 3.93 32.6 2.30 4.15 8.00
T*(8,L)X*C16 UC60C 47.5 3.58 3.89 32.6 2.34 4.08 8.10
T*(8,L)X*C20 UC60D 47.0 3.64 3.78 32.0 2.40 3.91 8.10
T*9X*C16 UC60C 47.5 3.58 3.89 32.6 2.34 4.08 8.00
T*9X*C20 UC60C 47.5 3.60 3.87 32.6 2.34 4.08 8.10
T*9X*D20 UC60D 46.5 3.60 3.79 32.0 2.38 3.94 8.10
(Y*9C/T*9V)*D20 FC/MC/PC60D 47.5 3.38 4.12 30.4 2.38 3.74 8.50
(Y*9C/T*9V)*D20 FC/MC62D 48.0 3.44 4.09 30.2 2.40 3.69 8.50
Y*(8,L)C*C16 FC/PC60C 47.5 3.40 4.09 30.4 2.40 3.71 8.50
Y*(8,L)C*C20 FC/PC60C 47.5 3.46 4.02 30.2 2.42 3.66 8.60
(Y*9C/T*9V)*C16 FC/PC60C 48.0 3.38 4.16 30.6 2.38 3.77 8.50
(Y*9C/T*9V)*C20 FC/PC60C 48.0 3.38 4.16 30.6 2.38 3.77 8.50
(Y*9C/T*9V)*D20 HC60 48.0 3.48 4.04 30.4 2.44 3.65 8.50
Y*(8,L)C*C16 HD60 47.0 3.22 4.28 30.2 2.24 3.95 8.40
Y*(8,L)C*C20 HD60 47.0 3.24 4.25 30.0 2.28 3.86 8.40
(Y*9C/T*9V)*C16 HD60 47.5 3.18 4.38 30.2 2.24 3.95 8.40
(Y*9C/T*9V)*C20 HD60 47.5 3.18 4.38 30.2 2.24 3.95 8.40
(Y*9C/T*9V)*D20 HD60 47.5 3.20 4.35 30.2 2.24 3.95 8.40
Y*(8,L)C*C16 UC60C 47.5 3.46 4.02 30.2 2.42 3.66 8.50
Y*(8,L)C*C20 UC60C 47.5 3.52 3.95 30.0 2.46 3.57 8.60
(Y*9C/T*9V)*C16 UC60C 48.0 3.44 4.09 30.4 2.42 3.68 8.50
(Y*9C/T*9V)*C20 UC60C 48.0 3.44 4.09 30.4 2.42 3.68 8.50
(Y*9C/T*9V)*D20 UC60D 48.0 3.44 4.09 30.2 2.42 3.66 8.50
YHJD60S41S1
T*(8,L)X*C20 FC/MC62D 56.5 3.60 4.60 32.6 2.46 3.88 8.10
T*9X*D20 FC/MC62D 56.5 3.44 4.81 34.0 2.34 4.26 8.00
(Y*9C/T*9V)*D20 FC/MC/PC60D 55.5 3.30 4.93 35.0 2.40 4.27 8.50
Y*(8,L)C*C20 FC/MC62D 55.5 3.42 4.76 34.6 2.44 4.16 8.60
(Y*9C/T*9V)*C20 FC/MC62D 56.0 3.36 4.88 35.0 2.40 4.27 8.60
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)
MODEL
FURNACE
MODEL
COIL
1
MODEL
ARI HEATING
2
47F17F HSPF
MBH COP KW MBH COP KW STD