TCGF42S41S1
MV16C 21 FC/MC43C 1400 41.0 30.8 15.00 12.75
MV16C 21 FC/MC48C 1400 41.5 31.2 15.50 13.00
MV20D 24 FC/MC48D 1400 42.0 31.4 15.50 13.00
MV20D 24 FC/MC60D 1400 41.5 31.4 15.50 13.00
MV20D 24 FC/MC62D 1400 42.0 31.4 15.75 13.00
TCGF48S41S1
MV16C 21 FC/MC48C 1600 47.0 33.0 15.25 12.75
MV20D 24 FC/MC48D 1600 47.0 33.0 15.25 12.75
MV20D 24 FC/MC60D 1600 47.0 33.0 15.25 12.75
MV20D 24 FC/MC62D 1600 47.5 33.2 15.25 12.75
TCGF60S41S1
MV20D 24 FC/MC60D 1800 55.0 39.0 14.00 11.95
MV20D 24 FC/MC62D 1800 57.0 39.5 14.50 12.25
14.5 SEER AC WITH AV / SV / F*FV - VARIABLE SPEED
TCGF24S41S1
AV24 17 - 750 25.0 17.5 15.75 13.25
AV36 21 - 750 25.8 18.2 16.50 13.75
TCGF30S41S1 AV36 21 - 1000 30.4 22.4 16.25 13.50
TCGF36S41S1
AV36 21 - 1250 36.2 27.4 15.75 13.25
AV/SV48 24 - 1200 34.4 25.4 15.25 13.00
F4FV060 24 - 1200 34.6 25.6 15.50 13.25
TCGF42S41S1
AV/SV48 24 - 1400 40.0 29.4 14.75 12.50
AV/SV60 24 - 1400 40.0 29.4 14.75 12.50
F4FV060 24 - 1350 40.0 29.6 15.00 12.50
TCGF48S41S1
AV/SV48 24 - 1600 44.5 30.8 14.25 12.00
AV/SV60 24 - 1650 44.0 30.6 14.25 12.00
F4FV060 24 - 1600 44.5 30.6 14.25 12.00
TCGF60S41S1 AV/SV60 24 - 1750 55.0 39.0 14.00 12.00
14.5 SEER AC WITH AHP / SHP / F*FP
TCGF24S41S1
AHP24 17 - 850 24.8 17.4 14.30 12.20
F4FP030 17 - 800 24.8 17.2 14.30 12.20
TCGF30S41S1 AHP36 21 - 1000 29.6 21.4 14.30 12.20
TCGF36S41S1
AHP36 21 - 1200 35.4 26.2 15.00 12.50
F4FP036 21 - 1200 34.2 25.2 14.00 12.00
F4FP040 21 - 1200 34.4 25.0 14.00 12.00
F4FP042 21 - 1200 34.4 25.0 14.00 12.00
F5FP048 24 - 1250 36.4 27.4 16.25 13.50
F5FP060 24 - 1250 34.8 26.0 15.25 13.00
TCGF42S41S1
F5FP048 24 - 1450 42.0 32.0 15.50 13.00
F5FP060 24 - 1500 40.0 29.8 14.75 12.50
TCGF48S41S1
AHP/SHP60 24 - 1600 44.0 30.6 14.20 12.00
F5FP048 24 - 1700 47.5 34.0 15.00 12.75
F5FP060 24 - 1700 44.5 31.2 14.00 12.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
COOLING
MODEL W
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.