York R-410A Air Conditioner User Manual


 
528194-YTG-F-1210
24 Johnson Controls Unitary Products
115°F 125°F
2500
77 117.2 11.2 54.3 43.9 33.2 - - - 104.6 12.1 64.4 42.9 31.5 - - -
72 106.1 10.8 74.7 63.9 53.2 42.5 - - 94.9 11.6 74.8 64.0 53.3 42.6 - -
67 95.0 10.4 95.0 84.0 73.3 62.6 51.8 - 85.2 11.1 85.2 85.2 75.2 64.5 53.8 -
62 85.5 10.1 85.5 85.5 81.6 70.9 60.1 49.4 76.3 10.8 76.3 76.3 76.3 70.2 59.4 48.7
3000
77 120.1 11.2 64.1 47.2 34.5 - - - 106.6 12.3 71.1 45.8 31.5 - - -
72 108.7 10.9 80.7 68.1 55.4 42.7 - - 96.7 11.7 78.9 66.3 53.7 41.0 - -
67 97.4 10.5 97.4 88.9 76.3 63.6 51.0 - 86.8 11.2 86.8 86.8 75.9 63.2 50.6 -
62 87.5 10.2 87.5 87.5 87.5 74.9 62.2 49.6 77.7 10.9 77.7 77.7 77.7 72.6 60.0 47.3
57 90.8 10.3 90.8 90.8 87.8 75.2 62.5 49.8 83.7 11.0 83.7 83.7 83.7 72.1 59.4 46.8
3500
77 122.9 11.3 73.9 50.5 35.9 - - - 108.6 12.4 77.9 48.7 31.5 - - -
72 111.3 10.9 86.8 72.2 57.6 43.0 - - 98.5 11.8 83.1 68.6 54.0 39.4 - -
67 99.7 10.6 99.7 93.9 79.3 64.7 50.1 - 88.4 11.3 88.4 88.4 76.5 62.0 47.4 -
62 89.6 10.3 89.6 89.6 93.5 78.9 64.3 49.7 79.2 11.0 79.2 79.2 79.2 75.0 60.5 45.9
57 93.0 10.4 93.0 93.0 91.3 76.7 62.1 47.5 85.3 11.1 85.3 85.3 85.2 70.6 56.1 41.5
4000
77 125.8 11.4 83.7 53.8 37.2 - - - 110.6 12.5 84.6 51.6 31.5 - - -
72 113.9 11.0 92.9 76.3 59.8 43.2 - - 100.3 11.9 87.3 70.8 54.3 37.8 - -
67 102.0 10.6 102.0 98.8 82.3 65.7 49.2 - 90.0 11.4 90.0 90.0 77.2 60.7 44.2 -
62 91.7 10.4 91.7 91.7 99.5 82.9 66.4 49.8 80.6 11.1 80.6 80.6 80.6 77.4 61.0 44.5
57 95.1 10.5 95.1 95.1 94.7 78.2 61.6 45.1 86.9 11.2 86.9 86.9 85.7 69.2 52.7 36.2
4500
72 115.9 11.1 99.2 81.4 63.6 45.8 - - 102.2 12.0 93.1 75.4 57.7 40.1 - -
67 103.8 10.7 103.8 102.2 87.6 69.8 52.0 - 91.7 11.5 91.7 91.7 82.0 64.4 46.7 -
62 93.3 10.4 93.3 93.3 97.2 79.4 61.6 43.8 82.2 11.1 82.2 82.2 82.2 71.2 53.5 35.8
57 96.8 10.5 96.8 96.8 96.6 78.8 61.0 43.2 88.5 11.3 88.5 88.5 87.9 70.3 52.6 34.9
5000
72 117.9 11.1 105.5 86.5 67.4 48.4 - - 104.2 12.1 98.9 80.0 61.2 42.3 - -
67 105.6 10.7 105.6 105.6 92.8 73.8 54.7 - 93.5 11.5 93.5 93.5 86.9 68.0 49.2 -
62 95.0 10.5 95.0 95.0 95.0 75.9 56.8 37.8 83.7 11.2 83.7 83.7 83.7 64.9 46.0 27.2
57 98.5 10.6 98.5 98.5 98.5 79.4 60.4 41.3 90.2 11.3 90.2 90.2 90.2 71.4 52.5 33.7
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
ZF120 (10 Ton) (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F) Return Dry Bulb (°F)
90 85 80 75 70 65 90 85 80 75 70 65