York H*RD036 THRU 060 Air Conditioner User Manual


 
254892-YTG-C-0606
12 Unitary Products Group
H2RD042S06
1200
1600
17,21 FC/MC/PC/UC42 1400 40.5 29.6 13.00 11.00
21,24 FC/MC/PC/UC48 1400 41.0 30.2 13.00 11.00
17 G*FA042S17 1400 40.5 29.6 13.00 11.00
21 G*FA048S21 1400 41.0 29.6 13.00 11.00
21 G*FD042H21 1400 40.5 29.6 13.00 11.00
17 G*FD046H17 1400 40.5 29.6 13.00 11.00
21,24 G*FD048H21,24 1400 41.0 30.2 13.00 11.00
21 HC48 1400 41.0 29.9 13.00 11.00
HD48 1400 41.5 29.5 13.00 11.00
H1RD042S(25,46)
1200
1600
17,21 FC/MC/PC/UC42 1400 39.5 28.9 13.00 11.00
21,24 FC/MC/PC/UC48 1400 40.0 29.5 13.00 11.00
17 G*FA042S17 1400 39.5 28.9 13.00 11.00
21 G*FA048S21 1400 40.0 28.9 13.00 11.00
21 G*FD042H21 1400 39.5 28.9 13.00 11.00
17 G*FD046H17 1400 39.5 28.9 13.00 11.00
21,24 G*FD048H21,24 1400 40.0 29.5 13.00 11.00
21 HC48 1400 40.0 29.2 13.00 11.00
- HD48 1400 40.5 28.8 13.00 11.00
H2RD048S06
1400
1800
21,24 FC/MC/PC/UC48 1600 47.0 35.1 13.00 11.00
21,24 G*FD048H21,24 1600 47.0 35.1 13.00 11.00
21 HC48 1600 46.5 35.0 13.00 11.00
HD48 1600 47.0 34.8 13.00 11.00
H1RD048S(25,46)
1400
1800
21,24 FC/MC/PC/UC48 1600 46.0 34.4 13.00 11.00
21,24 G*FA048S21 1600 46.0 34.4 13.00 11.00
21,24 G*FD048H21,24 1600 46.0 34.4 13.00 11.00
21 HC48 1600 45.5 34.3 13.00 11.00
HD48 1600 46.0 34.1 13.00 11.00
H2RD060S06
1600
2000
21,24 FC/MC/PC/UC60 1800 55.0 39.6 13.00 11.00
21,24 G*FA060S21,24 1800 55.0 39.6 13.00 11.00
24 G*FD060H24 1800 55.0 39.6 13.00 11.00
24 G*FD061H24 1800 55.5 39.6 13.00 11.00
24 MC61 1800 55.5 40.0 13.00 11.00
24 HC60 1800 55.0 39.6 13.00 11.00
HD60 1800 55.0 39.9 13.00 11.00
H1RD060S(25,46)
1600
2000
21,24 FC/MC/PC/UC60 1800 54.5 39.3 13.00 11.00
21,24 G*FA060S21,24 1800 54.5 39.3 13.00 11.00
24 G*FD060H24 1800 54.5 39.3 13.00 11.00
24 G*FD061H24 1800 54.5 39.3 13.00 11.00
24 MC61 1800 55.0 39.7 13.00 11.00
24 HC60 1800 54.5 39.3 13.00 11.00
HD60 1800 54.5 39.6 13.00 11.00
1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
** Refer to Quick Selection Chart for specific furnace match-up.
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Continued)
UNIT MODEL
FURNACE**
COIL
MODEL
COOLING
CFM RANGE
(MIN.-MAX.)
W
RATED
CFM
NET MBH
SEER
1
EER
TOTAL SENS.