York B6CH 048 Heat Pump User Manual


 
036-21564-002-A-0404
4 Unitary Products Group
COOLING CAPACITIES - 3 TON (BCH036)
Air On
Indoor
Coil
Temperature of Air on Outdoor Coil
85 °F95°F
Total
Cap.
1
MBH
Power
Input
2
KW
Sensible Capacity
1
, MBH
Total
Cap.
1
MBH
Power
Input
2
KW
Sensible Capacity
1
, MBH
CFM
WB
°F
Entering Dry Bulb, °F Entering Dry Bulb, °F
86 83 80 77 74 71 68 86 83 80 77 74 71 68
1750
72 51 3.4 37 32 28 24 19 - - 47 3.7 34 29 25 22 17 - -
67 46 3.4 40 40 36 31 26 21 16 44 3.7 38 38 34 29 24 20 15
62 42 3.3 42 42 41 39 34 29 24 38 3.6 38 38 37 35 30 26 21
57 42 3.3 42 42 42 40 35 30 25 37 3.6 37 37 37 35 30 26 22
1500
72 49 3.4 35 30 26 22 18 - - 46 3.7 32 28 24 20 16 - -
67 45 3.4 39 37 33 29 24 20 15 42 3.7 36 34 30 27 22 18 14
62 41 3.3 41 41 40 37 32 28 24 37 3.6 37 37 36 33 28 25 21
57 41 3.3 41 41 41 38 34 29 25 36 3.6 36 36 36 33 29 25 21
1400
72 48 3.4 33 29 24 20 16 - - 45 3.7 30 27 22 18 15 - -
67 44 3.3 39 36 32 28 23 20 15 41 3.7 36 33 29 26 21 18 13
62 40 3.3 40 39 38 34 30 26 22 36 3.6 36 35 34 30 27 23 19
57 40 3.3 40 40 39 35 31 27 23 36 3.5 36 36 35 31 27 24 20
1200
72 47 3.4 31 27 24 20 16 - - 44 3.7 29 25 22 18 14 - -
67 41 3.3 36 32 29 25 22 18 14 39 3.6 34 30 27 23 20 17 13
62 38 3.3 38 37 36 32 29 25 21 35 3.6 35 34 33 29 26 23 19
57 37 3.3 37 37 36 33 30 26 22 35 3.5 35 35 34 31 28 24 20
1050
72 45 3.3 28 25 22 19 16 - - 42 3.6 26 23 20 17 14 - -
67 41 3.3 34 30 27 24 20 17 14 38 3.6 31 27 25 22 18 15 12
62 36 3.3 36 35 33 30 27 24 21 34 3.5 34 33 31 28 25 22 19
57 36 3.3 36 36 34 31 28 25 22 33 3.5 33 33 31 28 25 22 20
900
72 45 3.3 26 24 20 17 15 - - 40 3.6 23 21 17 15 13 - -
67 39 3.3 31 28 25 22 19 17 14 35 3.6 27 25 22 19 17 15 12
62 35 3.2 35 34 32 29 25 23 20 32 3.5 32 30 28 25 22 20 17
57 35 3.2 35 35 32 30 26 24 21 31 3.5 31 31 28 26 23 21 18
Air On
Indoor
Coil
Temperature of Air on Outdoor Coil
105 °F115°F
Total
Cap.
1
MBH
Power
Input
2
KW
Sensible Capacity
1
, MBH
Total
Cap.
1
MBH
Power
Input
2
KW
Sensible Capacity
1
, MBH
CFM
WB
°F
Entering Dry Bulb, °F Entering Dry Bulb, °F
86 83 80 77 74 71 68 86 83 80 77 74 71 68
1750
72 44 4.0 31 27 24 20 16 - - 42 4.2 30 26 23 19 15 - -
67 40 4.0 34 34 31 26 22 18 13 36 4.1 31 31 28 24 20 16 12
62 35 3.9 35 35 34 32 28 24 20 34 4.1 34 34 33 31 27 23 19
57 35 3.9 35 35 35 33 29 25 20 33 4.1 33 33 33 31 27 23 19
1500
72 43 4.0 30 26 22 19 15 - - 41 4.2 29 25 21 18 15 - -
67 38 4.0 32 31 27 24 20 16 12 35 4.1 30 28 25 22 18 15 11
62 34 3.9 34 34 33 30 26 23 19 33 4.1 33 33 32 29 25 22 19
57 34 3.9 34 34 34 31 28 24 20 32 4.1 32 32 32 29 26 22 19
1400
72 42 4.0 28 25 21 17 14 - - 39 4.2 26 23 19 16 13 - -
67 37 4.0 32 30 26 23 19 16 12 34 4.1 30 27 24 21 17 15 11
62 33 3.9 33 32 31 28 24 21 18 32 4.1 32 31 30 27 24 20 17
57 32 3.8 32 32 31 28 24 21 18 32 4.0 32 32 31 28 24 21 18
1200
72 41 4.0 27 23 20 17 13 - - 37 4.2 24 21 18 15 12 - -
67 35 3.9 30 27 24 21 18 15 11 32 4.1 28 24 22 19 17 14 10
62 32 3.9 32 31 30 26 24 21 17 30 4.1 30 29 28 25 22 19 16
57 31 3.8 31 31 31 27 25 21 18 29 4.0 29 29 29 25 23 20 17
1050
72 40 3.9 24 22 19 16 14 - - 35 4.1 21 19 17 14 12 - -
67 34 3.9 28 24 22 19 16 14 11 31 4.0 25 22 20 18 15 12 10
62 30 3.8 30 29 27 25 22 20 17 29 4.0 29 28 26 24 21 19 16
57 30 3.8 30 30 28 25 23 20 18 28 4.0 28 28 26 24 21 19 17
900
72 38 3.9 21 20 16 14 12 - - 34 4.1 19 18 15 12 11 - -
67 32 3.9 25 22 20 18 15 13 11 29 4.0 23 20 18 16 14 12 10
62 29 3.8 29 27 25 23 20 18 16 27 4.0 27 25 24 21 18 17 15
57 29 3.8 29 29 26 24 21 19 17 26 4.0 26 26 23 22 19 17 15
1
These capacities are gross ratings. For net capacity, determine the KW of the supply air blower motor from the Blower Performance Table, multiply this value by
3.415 MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit.
2
These ratings include the compressor and the outdoor fan motors but not the supply air blower motor. The total outdoor fan motor power input is 0.35 KW.
Refer to the Blower Performance Table for the KW of the supply air blower motor.
ALL SENSIBLE CAPACITY
NOMINAL RATING