York 2000 Heat Pump User Manual


 
036-21564-003-A-1005
Unitary Products Group 5
COOLING CAPACITIES - 4 TON (BCH048)
Air On
Indoor
Coil
Temperature of Air on Outdoor Coil
85 °F95°F
Total
Cap.
1
MBH
Power
Input
2
KW
Sensible Capacity
1
, MBH
Total
Cap.
1
MBH
Power
Input
2
KW
Sensible Capacity
1
, MBH
CFM
WB
°F
Entering Dry Bulb, °F Entering Dry Bulb, °F
86 83 80 77 74 71 68 86 83 80 77 74 71 68
2000
72 56 4.1 42 36 31 26 - - - 53 4.5 40 35 29 24 - - -
67 53 4.0 48 47 41 36 30 25 - 51 4.4 46 45 41 35 30 24 -
62 49 4.0 49 49 48 44 38 33 28 46 4.3 46 46 45 41 35 30 24
57 49 3.9 49 49 49 44 38 33 28 46 4.3 46 46 46 41 35 30 24
1800
72 55 4.0 40 35 30 25 - - - 53 4.4 38 33 28 23 - - -
67 52 4.0 47 44 39 34 29 24 - 51 4.4 44 44 39 34 29 24 -
62 48 3.9 48 48 47 43 38 33 28 47 4.3 47 47 45 40 36 31 26
57 48 3.9 48 48 48 43 38 33 28 45 4.2 45 45 45 40 35 30 25
1600
72 53 4.0 37 33 28 24 - - - 52 4.4 36 32 27 23 - - -
67 51 4.0 46 42 37 33 28 24 - 50 4.3 44 43 38 34 29 25 -
62 47 3.9 47 47 46 41 37 32 28 45 4.2 45 45 44 40 36 31 27
57 47 3.9 47 47 47 42 38 33 29 44 4.1 44 44 44 40 36 31 27
1400
72 52 4.0 34 30 26 22 - - - 49 4.3 33 29 25 21 - - -
67 49 3.9 42 38 34 30 26 22 - 47 4.2 42 38 34 30 26 22 -
62 46 3.8 46 45 42 38 34 30 26 43 4.1 43 42 40 36 32 28 24
57 45 3.8 45 45 43 39 35 31 27 42 4.1 42 42 40 36 32 28 24
1200
72 50 3.9 31 27 24 20 - - - 47 4.2 29 25 22 18 - - -
67 47 3.9 38 35 31 28 24 21 - 45 4.2 37 34 30 27 23 20 -
62 44 3.8 44 42 39 35 32 28 25 40 4.1 40 39 36 32 29 25 22
57 44 3.7 44 43 39 36 32 29 25 40 4.0 40 39 36 32 29 25 22
Air On
Indoor
Coil
Temperature of Air on Outdoor Coil
105 °F115°F
Total
Cap.
1
MBH
Power
Input
2
KW
Sensible Capacity
1
, MBH
Total
Cap.
1
MBH
Power
Input
2
KW
Sensible Capacity
1
, MBH
CFM
WB
°F
Entering Dry Bulb, °F Entering Dry Bulb, °F
86 83 80 77 74 71 68 86 83 80 77 74 71 68
2000
72 51 4.9 40 35 29 24 - - - 49 5.2 39 34 29 23 - - -
67 46 4.7 42 42 39 34 28 23 - 41 5.0 40 40 37 32 26 21 -
62 43 4.6 43 43 42 37 32 27 21 40 4.9 40 40 39 34 29 23 18
57 43 4.6 43 43 43 38 32 28 22 40 4.8 40 40 40 34 30 24 19
1800
72 50 4.8 38 33 28 23 - - - 47 5.1 37 32 27 22 - - -
67 45 4.7 41 41 37 32 27 22 - 40 4.9 37 36 35 30 25 20 -
62 42 4.6 42 42 41 37 32 27 22 39 4.8 39 39 37 34 29 24 19
57 42 4.5 42 42 42 37 33 27 23 38 4.7 38 38 38 33 30 25 20
1600
72 49 4.8 35 31 26 22 - - - 46 5.1 34 29 25 20 - - -
67 44 4.6 40 40 35 31 26 22 - 39 4.9 36 36 32 28 23 19 -
62 41 4.5 41 41 40 35 32 27 23 37 4.7 37 37 36 33 28 24 19
57 41 4.4 41 41 41 36 32 28 23 37 4.7 37 37 37 34 28 25 20
1400
72 47 4.7 32 28 24 20 - - - 44 5.0 31 27 23 19 - - -
67 42 4.5 38 36 32 28 24 20 - 37 4.8 36 34 30 26 21 17 -
62 39 4.4 39 38 37 33 28 25 20 36 4.7 36 35 34 30 26 22 18
57 39 4.4 39 39 37 33 29 25 21 36 4.6 36 36 34 31 26 23 19
1200
72 44 4.6 28 25 21 18 - - - 42 4.9 28 24 21 17 - - -
67 40 4.5 36 32 29 25 22 18 - 36 4.7 34 31 27 24 20 17 -
62 38 4.4 38 36 34 29 27 22 20 35 4.6 35 34 30 28 24 20 17
57 37 4.3 37 37 34 30 27 23 20 35 4.6 35 35 31 29 24 21 18
1
These capacitiesare gross ratings.For net capacity, determinethe KW of thesupply air blowermotor from theBlower Performance Table,multiply this value by
3.415 MBH/ KW todetermine the motor heat,and deduct thisheat from thegross capacity ofthe unit.
2
These ratingsinclude the compressorand the outdoor fanmotors but notthe supply airblower motor. Thetotal outdoor fanmotor power inputis 0.35 KW.
Refer tothe Blower PerformanceTable for the KWof the supplyair blower motor.
ALLSENSIBLE CAPACITY
NOMINALRATING