York 1-1/2 THRU 5 TON (10 SEER) Air Conditioner User Manual


 
LIMITATIONS
These units must be installed in accordance with the following
national and local safety codes.
1. National Electrical Code ANSI/NFPS No. 70 or Canadian
Electrical Code Part 1, C22.1 (latest editions).
2. Local plumbing and waste water codes and other applica
-
ble local codes.
Refer to Table 1 for unit application data and to Table 5 for elec-
tric heat application data.
If components are to be added to a unit to meet local codes, they
are to be installed at the dealer'sand/orthecustomer'sexpense.
Size of unit for proposed installation should be based on heat
loss/heat gain calculations made in accordance with industry
recognized procedures identified by the Air Conditioning Con-
tractors of America.
LOCATION
Use the following guidelines to select a suitable location for
these units.
1. Unit is designed for outdoor installation only.
2. Condenser must have an unlimited supply of air. Where a
choice of location is possible, position unit on either north or
east side of building.
3. For ground level installation, a level pad or slab should be
used. The thickness and size of the pad or slab used should
meet local codes and unit weight. Do not tie the slab to the
building foundation.
4. For roof top installation, be sure the structure will support
the weight of the unit plus any field installed components.
Unit must be installed on a level roof curb or appropriate an
-
gle iron frame providing adequate support under the
compressor/condenser section.
5. Maintain level tolerance of unit to 1/8" maximum.
RIGGING OR HANDLING
Care must be exercised when moving the unit. Do not remove
any packaging until the unit is near the place of installation. Rig
unit with slings placed under the unit. Spreader bars of suffi-
cient length should be used across the top of the unit.
BEFORE LIFTING A UNIT, MAKE SURE THAT ITS WEIGHT
IS DISTRIBUTED EQUALLY ON THE CABLES SO THAT IT
WILL LIFT EVENLY.
Units may also be moved or lifted with a fork-lift. Slotted open-
ings in the skid are provided for this purpose. Forks must pass
completely through the base.
Refer to Table2forunitweightsandtoFigure1forapproximate
center of gravity.
035-16703-001-A-0202
2 Unitary Products Group
Voltage Variation
Min. / Max
.1
208/230V
3
187 / 253
3
460V 414 / 504
575V 518 / 630
Wet Bulb Temperature (°F) of Air on
Evaporator Coil, Min. / Max.
57 / 72
Dry Bulb Temperature (°F) of Air on
Condenser Coil, Min.
2
/ Max.
45 / 120
1
Rated in accordance with ARI Standard 110, utilization range “A”.
2
A low ambient accessory is available for operation down to 0°F
3
“T1" transformer primary tap must be moved from the 230 volt connection to the 208 volt
connection for low voltage applications of 208 volt and below.
TABLE 1 - UNIT APPLICATION DATA
FIG. 1 - CENTER OF GRAVITY
26
CENTER OF GRAVITY
FRONT
OF
UNIT
“A”
“B”
“C”
“D”
UNIT
SIZE
SHIPPING
WEIGHT
(lbs.)
OPERAT
-
ING
WEIGHT
(lbs.)
CORNER WEIGHTS
(location, lbs.)
“A” “B” “C” “D”
018 318 313 86 76 73 83
024 324 319 88 77 75 85
030 333 328 85 81 82 86
036 338 333 91 80 78 88
042 347 342 94 83 80 91
048 368 363 92 88 92 97
060 376 371 105 100 84 87
TABLE 2 - UNITS WEIGHTS
D
1 E B A
PRODUCT NOMENCLATURE
PRODUCT GENERATION
1 = NEW or Current Design
PRODUCT CATEGORY
D = Single Package Air Conditioner
(Air Cooled)
PRODUCT IDENTIFIER
EB = 10 SEER Cooling Models
20 4 0 6
FACTORY
INSTALLED ELECTRIC HEAT
A = No Electric Heat Installed
VOLTAGE CODE
06 = 208/230-1-60
25 = 208/230-3-60
46 = 460-3-60
58 = 575-3-60
NOMINAL COOLING
CAPACITY (MBH)
018 = 18,000 BTUH
024 = 24,000 BTUH
030 = 30,000 BTUH
036 = 36,000 BTUH
042 = 42,000 BTUH
048 = 48,000 BTUH
060 = 60,000 BTUH
INSTALLATION