York 036-048 Heat Pump User Manual


 
279104-YTG-B-0307
14 Unitary Products Group
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO E1RA060S(25,46)
EVAPORATOR COIL MODEL NO G2FD060(S,H)24
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
ID CFM
1600 1800 2000
MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P.
60
60 63.65.093.6761.94.983.6460.14.873.62
70 64.85.333.5663.55.183.5962.25.043.62
80 65.95.603.4565.15.393.5464.25.203.62
47
60 56.94.154.0355.74.024.0654.43.904.10
70 58.34.623.7058.04.543.7556.34.353.80
80 59.75.193.3859.05.033.4458.24.883.50
40
60 54.54.053.9553.33.933.9752.03.814.00
70 53.74.413.5753.44.323.6353.24.223.69
80 52.94.873.1953.64.783.2954.34.713.38
30
60 49.63.893.7449.83.803.8449.93.723.93
70 47.74.183.3448.04.103.4448.44.023.53
80 45.84.572.9446.34.473.0446.84.393.13
17
60 40.63.563.3441.03.513.4241.33.463.50
70 38.83.862.9439.23.803.0239.73.743.11
80 36.94.262.5437.54.182.6338.04.102.71
10
60 36.3 3.53 3.01 36.7 3.46 3.11 37.1 3.38 3.21
70 34.33.822.6334.73.742.7235.23.672.81
80 32.24.192.2532.74.122.3333.24.052.40
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler Coil
MBH KW COP
MA20DN2,4 FC/MC60D3X 1.00 1.00 1.00
N1AHD2046 G2FD060(S,H)24 1.00 1.00 1.00
AHP/SHP60D3X 1.01 1.03 0.98
F2FP060 1.01 1.03 0.98
G1FA060S21,24 1.00 1.00 1.00
G1UA060S21,24 1.00 1.00 1.00
FC/MC/PC/UC60*3X 1.00 1.00 1.00