York 036-048 Heat Pump User Manual


 
279104-YTG-B-0307
Unitary Products Group 13
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO E2RA048S(25,46)
EVAPORATOR COIL MODEL NO F2RP/F2FP048
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
ID CFM
1250 1400 1550
MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P.
60
60 53.44.863.2352.94.723.2852.24.253.61
70 54.24.763.3454.14.613.4453.74.143.80
80 54.15.572.8554.45.392.9654.44.833.30
47
60 47.04.543.0346.64.453.0746.54.053.36
70 46.94.563.0247.04.473.0847.24.063.41
80 46.35.242.5946.95.132.6847.34.652.98
40
60 37.73.543.1242.94.312.9243.43.933.24
70 37.33.982.7542.94.402.8642.64.133.02
80 36.65.791.8542.55.002.5040.05.472.14
30
60 37.74.012.7638.74.032.8237.93.703.00
70 36.74.162.5838.24.222.6538.43.932.86
80 35.34.602.2537.34.702.3338.74.442.55
17
60 32.23.672.5732.73.682.6133.03.402.85
70 30.83.982.2731.43.972.3231.83.662.55
80 29.44.302.0030.14.292.0630.63.942.28
10
60 29.23.462.4829.63.462.5130.13.192.77
70 27.53.812.1227.93.802.1528.43.512.37
80 25.84.021.8826.34.021.9226.73.712.12
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler Coil
MBH KW COP
MA16CN2,4 FC/MC48C3X 1.00 1.00 0.97
N1AHC1646 G2FD048(S,H)21 1.00 1.02 0.98
MA20DN2,4 MC48D3X 1.00 1.02 0.98
N1AHD2046 G2FD048(S,H)24 1.00 1.02 0.98
AHP/SHP48D3X 1.01 1.02 0.99
F2FP060 1.01 1.02 0.99
G1FA048S21 1.00 1.02 0.98
G1NA048S21D 1.00 1.04 0.96
G1UA048S21 1.00 1.03 0.97
FC/MC/PC/UC48C,D3X 1.00 1.03 0.97
G2FD048(S,H)21,24 1.00 1.03 0.97